Your browser doesn't support javascript.
loading
EndoFLIP: una nueva tecnología / EndoFLIP: a new technology
Hani, Albis; Delgado, Andrés; Bejarano, Janeth; Meza, Diana; Ramírez, Rosangela; Pinto, Mariano; Córdoba, Jeiler; Buitrago, Andrea; Amaris, Amaury; Ardila, Carolina.
  • Hani, Albis; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Delgado, Andrés; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Bejarano, Janeth; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Meza, Diana; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Ramírez, Rosangela; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Pinto, Mariano; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Córdoba, Jeiler; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Buitrago, Andrea; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Amaris, Amaury; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
  • Ardila, Carolina; Pontificia Universidad Javeriana. Hospital Universitario San Ignacio. Bogotá. CO
Rev. colomb. gastroenterol ; 36(2): 227-240, abr.-jun. 2021. tab, graf
Article Dans Anglais, Espagnol | LILACS | ID: biblio-1289303
RESUMEN
Resumen Mediante la distensión de un balón con líquido conductor, la sonda de imagen luminal funcional endoluminal (EndoFLIP) evalúa las propiedades biomecánicas como la distensibilidad, volumen, presión e inclusive diámetros de regiones esfinterianas como la unión gastroesofágica, píloro y ano. La mayor evidencia en la utilidad clínica de la EndoFLIP está en los trastornos de motilidad esofágica, principalmente para identificar acalasia cuando la manometría esofágica de alta resolución y otras imágenes no logran diagnosticarla e inclusive, mediante el programa de FLIP 2.0, caracteriza la acalasia en subtipos a partir de patrones de motilidad del esófago distal en respuesta a la distensión. Se ha demostrado recientemente que la EndoFLIP tiene un rol diagnóstico, pronóstico o terapéutico en otras patologías como la esofagitis eosinofílica, reflujo gastroesofágico, gastroparesia, durante la fundoplicatura y dilatación esofágica.
ABSTRACT
Abstract EndoFLIP evaluates biomechanical properties such as distensibility, volume, pressure, and even diameters of sphincter regions like the gastroesophageal junction, pylorus, and anus, by distending a balloon with a conductive medium. The best evidence of the clinical utility of EndoFLIP is observed in esophageal motility disorders, mainly when identifying achalasia when high-resolution esophageal manometry and other images fail to diagnose it. Even EndoFLIP 2.0 characterizes achalasia into subtypes based on distal esophageal motility patterns in response to distention. Recently, it has been shown that this system has a diagnostic, prognostic and/or therapeutic role in other diseases such as eosinophilic esophagitis, gastroesophageal reflux, and gastroparesis, and during fundoplication and esophageal dilation.
Sujets)


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dyskinésies oesophagiennes / Achalasie oesophagienne Limites du sujet: Humains langue: Anglais / Espagnol Texte intégral: Rev. colomb. gastroenterol Thème du journal: Gastroentérologie Année: 2021 Type: Article Pays d'affiliation: Colombie Institution/Pays d'affiliation: Pontificia Universidad Javeriana/CO

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dyskinésies oesophagiennes / Achalasie oesophagienne Limites du sujet: Humains langue: Anglais / Espagnol Texte intégral: Rev. colomb. gastroenterol Thème du journal: Gastroentérologie Année: 2021 Type: Article Pays d'affiliation: Colombie Institution/Pays d'affiliation: Pontificia Universidad Javeriana/CO