Achados ao ecocardiograma transtorácico em pacientes hospitalizados com COVID- 19: resultados do registro brasileiro de ecocardiografia durante a pandemia de COVID-19 (ECOVID) / Transthoracic echocardiography findings of hospitalized patients with COVID-19: results from the brazilian echocardiography registry during the COVID-19 Pandemic (ECOVID)
ABC., imagem cardiovasc
;
34(4): eabc256, 2021. tab
Article
Dans Portugais
| LILACS
| ID: biblio-1359750
RESUMO
Fundamento A ecocardiografia transtorácica (ETT) pode desempenhar um papel crucial na avaliação das manifestações cardíacas da COVID-19. Objetivo:
Nosso objetivo foi relatar a prevalência das principais anormalidades ecocardiográficas em pacientes hospitalizados com COVID-19.Métodos:
Realizou-se estudo observacional multicêntrico prospectivo com pacientes com COVID-19 submetidos a ETT durante a internação. Pacientes com insuficiência cardíaca prévia, doença arterial coronariana ou fibrilação atrial foram classificados como portadores de doença cardiovascular (DCV) prévia. Foram coletados dados clínicos e ecocardiográficos da estrutura e da função cardíaca.Resultados:
Avaliamos 310 pacientes com COVID-19, com 62±16 anos de idade, 61% homens, 53% com hipertensão arterial, 33% com diabetes e 23% com DCV prévia. No total, 65% dos pacientes necessitaram de suporte em unidade de terapia intensiva. As alterações ecocardiográficas mais prevalentes foram hipertrofia do ventrículo esquerdo (VE) (29%), hipertensão pulmonar (25%), disfunção sistólida do VE (16,5%), disfunção sistólica do ventrículo direito (VD) (15,9%), disfunção diastólica do VE grau II/III (11%) e alteração da contratilidade regional do VE (11%). Derrame pericárdico foi incomum (7%). Hipertrofia do VE (25 vs. 45%, p=0,001), disfunção sistólica do VE (11 vs. 36%, p<0,001), alterações da contratilidade regional (6 vs. 29%, p<0,001), disfunção diastólica do VE grau II/III (9 vs. 19%, p=0,03) e hipertensão pulmonar (22 vs. 36%, p=0,019) foram menos comuns nos pacientes sem do que com DCV prévia. A disfunção sistólica do VD mostrou-se semelhante em pacientes sem e com DCV prévia (13 vs. 25%, p=0,07).Conclusões:
Entre os pacientes hospitalizados com COVID-19, os achados ecocardiográficos anormais foram comuns, porém menos encontrados naqueles sem DCV. A disfunção sistólica do VD pareceu afetar de forma semelhante pacientes com e sem DCV prévia. (AU)ABSTRACT
Background:
Transthoracic echocardiography (TTE) may play a crucial role in the evaluation of cardiac manifestations of coronavirus disease 2019 (COVID-19).Objective:
We aimed to report the prevalence of the main echocardiographic abnormalities of hospitalized COVID-19 patients.Methods:
We performed a prospective multicenter observational study in patients with COVID-19 who underwent TTE during hospitalization. Patients with pre-existing heart failure, coronary artery disease, or atrial fibrillation were categorized as having previous cardiovascular disease (CVD). Clinical and echocardiographic data about cardiac structure and function were collected.Results:
We evaluated 310 patients with COVID-19 (mean age, 62±16 years; 61% men; 53% with arterial hypertension; 33% with diabetes; and 23% with previous CVD). Overall, 65% of the patients required intensive care unit support. The most prevalent echocardiographic abnormalities were LV hypertrophy (29%), pulmonary hypertension (25%), left ventricular (LV) systolic dysfunction (16.5%), right ventricular (RV) systolic dysfunction (15.9%), grade II/III LV diastolic dysfunction (11%), and LV regional wall motion abnormality (11%). Pericardial effusion was uncommon (7% of cases). LV hypertrophy (25% vs. 45%, p=0.001), LV systolic dysfunction (11% vs. 36%, p<0.001), regional wall motion abnormalities (6% vs. 29%, p<0.001), grade II/III LV diastolic dysfunction (9% vs. 19%, p=0.03), and pulmonary hypertension (22% vs. 36%, p=0.019) were less common in patients without previous CVD. RV systolic dysfunction occurred at similar frequencies in patients with versus without previous CVD (13% vs. 25%, p=0.07).Conclusions:
Among patients hospitalized with COVID-19, abnormal echocardiographic findings were common, but less so among those without previous CVD. RV systolic dysfunction appeared to affect similar proportions of patients with versus without previous CVD. (AU)
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Échocardiographie
/
COVID-19
/
Défaillance cardiaque
Type d'étude:
Essai clinique contrôlé
/
Etude diagnostique
/
Étude observationnelle
/
Facteurs de risque
/
Étude de dépistage
Limites du sujet:
Adolescent
/
Adulte
/
Humains
/
Mâle
Pays comme sujet:
Amérique du Sud
/
Brésil
langue:
Portugais
Texte intégral:
ABC., imagem cardiovasc
Thème du journal:
Cardiologie
/
Imagerie diagnostique
Année:
2021
Type:
Article
Pays d'affiliation:
Brésil
Institution/Pays d'affiliation:
CardioEco - Centro de Diagnóstico Cardiovascular/BR
/
Hospital Mãe de Deus/BR
/
Hospital Nossa Senhora das Graças/BR
/
Hospital Samaritano/BR
/
Hospital Samel/BR
/
Hospital Sirio Libanês/BR
/
Hospital Universitário Getúlio Vargas/BR
/
Hospital Universitário da Universidade Estadual de Londrina HUUEL/BR
/
Hospital Universitário da Universidade Federal do Vale do São Francisco/BR
/
Hospital de Clínicas da Universidade Federal do Paraná-UFPR/BR
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS