Implante de válvula aórtica percutánea en paciente con prótesis mitral previa: riesgos y consideraciones técnicas / Successful deployment of a percutaneous aortic valve in a patient with a mitral prosthesis: risks and technical considerations
Rev. méd. Chile
;
149(2): 286-290, feb. 2021. ilus
Article
Dans Espagnol
| LILACS
| ID: biblio-1389442
ABSTRACT
The deployment of a percutaneous aortic valve is challenging in patients with a mitral prosthesis. The risk of prosthetic deformation, embolization or dysfunction is higher in this group of patients, which requires a series of technical considerations. We report a successful implantation of an Evolut Pro # 29 self-expanding valve in a 67-year-old female with a previous Starr-Edwards caged-ball mitral prosthesis.
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Prothèse valvulaire cardiaque
/
Implantation de valve prothétique cardiaque
Limites du sujet:
Adulte très âgé
/
Femelle
/
Humains
langue:
Espagnol
Texte intégral:
Rev. méd. Chile
Thème du journal:
Médicament
Année:
2021
Type:
Article
Pays d'affiliation:
Chili
Institution/Pays d'affiliation:
Hospital Sótero del Río/CL
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS