Your browser doesn't support javascript.
loading
Effect of low temperature and room temperature on the depth of cure of bulk-fill composite resins
Ferreira, Anna Flávia Esteves; Silva, Ingrid Melo; Dietrich, Lia; Costa, Marcelo Dias Moreira de Assis; Andrade, Cláudia Maria de Oliveira; Martins, Victor da Mota.
  • Ferreira, Anna Flávia Esteves; Faculty Patos de Minas. Patos de Minas. BR
  • Silva, Ingrid Melo; Faculty Patos de Minas. Patos de Minas. BR
  • Dietrich, Lia; Federal University of Vale do Jequitinhonha and Mucuri. Diamantina. BR
  • Costa, Marcelo Dias Moreira de Assis; Federal University of Uberlândia. Uberlândia. BR
  • Andrade, Cláudia Maria de Oliveira; University Center of Patos de Minas. Patos de Minas. BR
  • Martins, Victor da Mota; University Center of Patos de Minas. Patos de Minas. BR
Biosci. j. (Online) ; 39: e39018, 2023. ilus, tab
Article Dans Anglais | LILACS | ID: biblio-1415912
ABSTRACT
The study analyzed the influence of temperature on the depth of cure of bulk-fill composite resins. Three discs (ISO 4049/2000) from each group were made, and four restorative materials were investigated Opus Bulk-Fill Flow, Opus Bulk-Fill APS, Filtek™ One Bulk-Fill, and Filtek™ Bulk-Fill Flow. They were light-cured (Gnatus ± 1,200 mW/cm2) for 20 seconds, varying the temperature (23°C and 5°C) and simulating the use of the product both at room temperature and under refrigeration. The materials were inserted in aluminum matrices with 10 mm in depth and 4 mm in diameter. A clear film strip and a glass microscope slide were positioned at the top and bottom surfaces. The material was condensed and light-cured with the tip of the light source in close contact, for 20 seconds on the top surface. Immediately after irradiation, the samples were removed from the mold, and the uncured part was removed with a plastic spatula. The measurement was performed with a micrometer ± 0.1 mm, and the value was divided by 2. The data were analyzed with two-way ANOVA at a significance of 0.05. There was a statistical difference in the temperature between the results obtained in Opus Bulk-Fill APS (p <0.001) and Filtek™ Bulk-Fill Flow (p = 0.018) resins. For the temperature of 5°C, Filtek™ Bulk-Fill Flow showed a statistical difference compared to the other resins, while Opus Bulk-Fill Flow and Opus Bulk-Fill APS did not. For the temperature of 23°C, Filtek™ Bulk-Fill Flow maintained the statistical difference from the others, but Filtek™ One Bulk-Fill and Opus Bulk-Fill APS did not present statistical differences. Storing the Filtek™ Bulk-Fill Flow composite resin in the refrigerator caused a greater depth of cure than the other resins, and the depth of cure decreased at room temperature. As for Opus Bulk-Fill APS, the depth of cure decreased proportionally to the temperature decrease. The temperature may affect the depth of cure of some composite resins.

C - All Rights Reserved
Sujets)


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Température / Basse température / Résines composites / Polymérisation langue: Anglais Texte intégral: Biosci. j. (Online) Thème du journal: Agricultura / Disciplinas das Ciˆncias Biol¢gicas / Pesquisa Interdisciplinar Année: 2023 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Faculty Patos de Minas/BR / Federal University of Uberlândia/BR / Federal University of Vale do Jequitinhonha and Mucuri/BR / University Center of Patos de Minas/BR

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Température / Basse température / Résines composites / Polymérisation langue: Anglais Texte intégral: Biosci. j. (Online) Thème du journal: Agricultura / Disciplinas das Ciˆncias Biol¢gicas / Pesquisa Interdisciplinar Année: 2023 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Faculty Patos de Minas/BR / Federal University of Uberlândia/BR / Federal University of Vale do Jequitinhonha and Mucuri/BR / University Center of Patos de Minas/BR