RESUMO
RESUMO Objetivo Identificar alterações de aberrometria de alta ordem em diferentes graus de ceratocone. Métodos Estudo transversal, retrospectivo, observacional. Foram analisados 54 pacientes (108 olhos) diagnosticados com ceratocone pelo mesmo especialista em córnea por meio dos critérios ABCD de Belin/Ambrósio Enhanced Ectasia, utilizando-se o tomógrafo Pentacam® HR 70900 (Oculus Wetzlar, Alemanha). Além disso, foram feitas análises qualitativa e quantitativa das aberrações de alta ordem desses mesmos pacientes por meio do OPD-Scan III-NIDEK. Resultados Por meio da avaliação de ambos os olhos dos pacientes com os critérios de Belin-Ambrósio, constatou-se presença de ceratocone em 34 pacientes. Ademais, por meio da análise estatística, constatou-se relação direta entre a asfericidade posterior e o desenvolvimento do ceratocone, com p<0,001 (referência p<0,05). Por meio da análise do OPD-Scan III-NIDEK, as principais aberrações de alta ordem encontradas nos pacientes com ceratocone foram coma, trefoil e aberração esférica. Conclusão O raio da curvatura posterior é a primeira variável a se alterar com o desenvolvimento do ceratocone, o que se faz perceptível na análise da asfericidade posterior por meio o Pentacam®. Além disso, a alteração da paquimetria e da asfericidade posterior influencia diretamente o desenvolvimento de aberrações de alta ordem em pacientes com ceratocone.
ABSTRACT
ABSTRACT Objective To identify higher order aberrometry changes in different degrees of keratoconus. Methods Cross-sectional, retrospective, observational study. Fifty-four patients (108 eyes) diagnosed with keratoconus by the same corneal specialist using the Belin/Ambrósio Enhanced Ectasia ABCD criteria were analyzed, using the Pentacam® HR 70900 tomograph (Oculus Wetzlar, Germany). In addition, qualitative and quantitative analysis of higher order aberrations in these patients was performed using the OPD-Scan III-NIDEK. Results Through the evaluation of both eyes of the patients according to the criteria of Benin Ambrósio, the presence of KCN was verified in 34 patients. Furthermore, through statistical analysis, a direct relationship was found between posterior asphericity and the development of KCN; p<0.001 (reference p<0.05). Through the analysis of the OPD scan, the main higher order aberrations found in patients with KCN were Coma, Trefoil and Spherical Aberration (AE). Conclusion The posterior curvature radius is the first variable to change with the development of the KCN, which is noticeable in the analysis of posterior asphericity in Pentacam. In addition, alterations in pachymetry and posterior asphericity directly influence the development of higher order aberrations in patients with KCN.
Mots clés
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Aberrométrie
/
Kératocône
Type d'étude:
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Qualitative_research
/
Risk_factors_studies
Limites du sujet:
Adolescent
/
Adult
/
Aged
/
Female
/
Humans
/
Male
langue:
Pt
Texte intégral:
Rev. bras. oftalmol
Thème du journal:
OFTALMOLOGIA
Année:
2023
Type:
Article