Propuesta metodológica para el uso del programa PCXMC 2.0 en modalidad rotacional / Methodological Proposal for the use of the program PCXMC 2.0 in Rotational Mode
González, S; Arce, L; Ubeda, C.
  • González, S; Universidad de Tarapacá. Facultad de Ciencias de la Salud. Arica. CL
  • Arce, L; Hospital San Juan de Dios. Servicio de Radiología e Imágenes Médicas. CR
  • Ubeda, C; Universidad de Tarapacá. Facultad de Ciencias de la Salud. arica. CL
J.health med.sci. ; 9(3): 17-24, jul.2023. ilus, tab, graf
Article Dans Espagnol | LILACS | ID: biblio-1523952
RESUMEN
RESUMEN Durante los procedimientos intervencionistas que utilizan fluoroscopia, se entrega a los pacientes diferentes niveles de dosis de radiación, que pueden tener un impacto a corto, mediano o largo plazo, así como en su severidad. Esto en función del tipo de radiación utilizada y de la sensibilidad a la radiación del tipo(s) de órgano(s) irradiado, es en este punto que se vuelve determinante conocer la dosis a órganos entregada durante los procedimientos con el fin de asegurar el bienestar de los pacientes, este procedimiento no se puede realizar directamente en los órganos del paciente, por lo que se utilizan programas especializado en cálculos dosimétricos. El software PCXMC 2.0 logra estimar la dosis efectiva a través del método determinístico Monte Carlo, a su vez, agregando la dosis equivalente y evaluación de riesgo para estudios dosimétricos, por lo cual, el objetivo del presente trabajo fue proponer una metodología estandarizada para la utilización del programa PCXMC en el cálculo de estas dos magnitudes
ABSTRACT
ABSTRACT During interventional procedures that utilize fluoroscopy, patients are exposed to varying levels of radiation doses, which can have short, medium, or long term impacts, as well as varying severities. This depends on the type of radiation used and the radiation sensitivity of the organ(s) being irradiated. At this point, it becomes crucial to determine the organ doses delivered during procedures in order to ensure patient well-being. Since direct measurements cannot be made on the patient's organs, specialized software is used for dosimetric calculations. PCXMC 2.0 software achieves the estimation of effective dose through the deterministic Monte Carlo method, while also incorporating equivalent dose and risk assessment for dosimetric studies. Therefore, the objective of this work was to propose a standardized methodology for the use of the PCXMC 2.0 sofware in the calculation of these two magnitudes.it is important to outline a working method for this software and provide instructions on its operation
Sujets)

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dose de rayonnement / Logiciel / Radioscopie langue: Espagnol Texte intégral: J.health med.sci. Année: 2023 Type: Article Pays d'affiliation: Chili / Costa Rica Institution/Pays d'affiliation: Hospital San Juan de Dios/CR / Universidad de Tarapacá/CL

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dose de rayonnement / Logiciel / Radioscopie langue: Espagnol Texte intégral: J.health med.sci. Année: 2023 Type: Article Pays d'affiliation: Chili / Costa Rica Institution/Pays d'affiliation: Hospital San Juan de Dios/CR / Universidad de Tarapacá/CL