Concordancia inter- e intraobservador del puntaje PI-RADS 2.1 del Colegio Americano de Radiología / Intraobserver and interobserver agreement of the American College of Radiology PI-RADS 2.1 score
Múnera-Orozco, Valentina; Isaza-Zapata, Sebastián; Escobar, Luz A.; Peláez-Arroyave, Sebastián; Castrillón, Germán A..
  • Múnera-Orozco, Valentina; Centro de Diagnóstico Médico. Centro de Imágenes Diagnósticas. Medellín. CO
  • Isaza-Zapata, Sebastián; Centro de Diagnóstico Médico. Centro de Imágenes Diagnósticas. Medellín. CO
  • Escobar, Luz A.; Centro de Diagnóstico Médico. Centro de Imágenes Diagnósticas. Medellín. CO
  • Peláez-Arroyave, Sebastián; Centro de Diagnóstico Médico. Centro de Imágenes Diagnósticas. Medellín. CO
  • Castrillón, Germán A.; Centro de Diagnóstico Médico. Centro de Imágenes Diagnósticas. Medellín. CO
Rev. argent. radiol ; 88(1): 3-10, mar. 2024. tab, graf
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1550715
RESUMEN
Resumen Antecedentes La resonancia magnética (RM) de próstata es uno de los métodos diagnósticos para la identificación del carcinoma de próstata. La escala PI-RADS (Prostate Imaging and Reporting Data System) es el sistema usado para la interpretación de estas imágenes. Es importante, para su reproducibilidad, la estandarización y la evaluación de dicha escala.

Objetivo:

Determinar la concordancia inter- e intraobservador de la versión 2.1 del PI-RADS. Material y

métodos:

Estudio observacional retrospectivo, evaluando 129 RM de pacientes con sospecha de cáncer de próstata por tres radiólogos con diferentes años de experiencia y en dos momentos del tiempo, usando el puntaje PI-RADS 2.1. Se evaluó la concordancia intra- e interobservador.

Resultados:

La concordancia interobservador fue sustancial (kappa > 0,6) en todos los observadores, siendo la categoría 5 la de mayor acuerdo interobservador. Se observó una alta reproducibilidad intraobservardor, con la mayor kappa siendo de 0,856. Cuando se realizó el análisis según años de experiencia de los radiólogos, la concordancia interobservador fue significativa en todos los casos.

Conclusiones:

El sistema de clasificación PI-RADS 2.1 es reproducible para las diferentes categorías y aumenta la concordancia cuando se trata de lesiones con mayor probabilidad de cáncer clínicamente significativo.
ABSTRACT
Abstract

Background:

Magnetic Resonance Imaging (MRI) of the prostate is a key diagnostic tool for identifying prostate carcinoma. The Prostate Imaging-Reporting and Data System (PI-RADS) scale is the standard system for interpreting these images. Standardizing and evaluating this scale is crucial for ensuring consistent and reproducible results.

Objective:

This study aims to assess both the interobserver and intraobserver agreement of the PI-RADS version 2.1. Material and

methods:

In this retrospective observational study, 129 prostate MRI scans from patients with suspected prostate cancer were evaluated. Three radiologists, each with different levels of experience, analyzed these scans at two separate times using the PI-RADS 2.1 scoring system. Both intraobserver and interobserver agreements were measured.

Results:

The study found substantial interobserver agreement (kappa > 0.6) across all categories, with category 5 showing the highest level of agreement. Intraobserver reproducibility was also high, with the highest kappa value reaching 0.856. Further analysis based on the radiologists’ years of experience revealed significant interobserver agreement in all instances.

Conclusions:

The PI-RADS 2.1 classification system demonstrates high reproducibility across different categories, particularly for lesions more likely to be clinically significant cancers. This underscores its reliability in varied diagnostic scenarios.