RESUMO
A colagem de acessórios ortodônticos é considerada um dos fatores que mais interfere na expressão dos aparelhos pré-ajustados. Ambas as técnicas tradicionais de colagem, método direto e indireto, falham em alcançar a posição ideal. Novas perpectivas de refinamento dos protocolos têm sido apontadas pela incorporação de tecnologia digital ao processo indireto. Esse estudo comparou a acurácia da colagem de acessórios ortodônticos em ambiente virtual em relação ao procedimento direto, considerando o tempo de experiência clínica dos operadores. 1120 dentes artificiais, constituintes de 40 pares de modelos idênticos (20 conjuntos sólidos + 20 conjuntos digitais), foram igualmente distribuídos, em dois tempos distintos, entre dois grupos de profissionais grupo I CDO (colagem direta/clínicos experientes); grupo II CDA (colagem direta/pósgraduandos); grupo III CVO (colagem virtual/clínicos experientes); grupo IV CVA (colagem virtual/ pósgraduandos) As diferenças das posições individuais dos acessórios experimentais, em relação acessórios de referência validados para o estudo, foram aferidas após sobreposição tridimensional de modelos, em software customizado. Análises estatísticas foram conduzidas com nível de significância de 5%. O teste Mann-Whitney mostrou diferenças significativas entre as médias dos erros nas dimensões vertical (p = 0,029) e angulação (p = 0,041), entre os grupos I e II e na vertical (p =0,020) e angulação (p =0,019), entre os grupos III e IV; O teste de Wilcoxon pareado mostrou que as diferenças foram significantes nas dimensões vertical (p < 0,001) e horizontal (p < 0,001), entre os grupos I e III e na vertical (p = 0,006), entre os grupos II e IV; o teste qui-quadrado mostrou diferenças significantes nas prevalências dos desvios, em todas as dimensões (horizontal p < 0,002; vertical p < 0,001; angulação p < 0,001), com tempo de experiência sendo significativo na dimensão horizontal (p = 0,041). Ambos os grupos falharam na obtenção da acurácia. O percentual de erros na colagem virtual foi significativamente menor nas dimensões lineares (vertical e mésiodistal) e maior na angulação. O percentual de erro dos profissionais com maior tempo de experiência clínica foi menor na dimensão horizontal. O diagnóstico precoce de desvio nas posições de colagem pode beneficiar diretamente profissional e paciente, ao antever discrepâncias passíveis de movimentos ortodônticos indesejáveis.(AU)
ABSTRACT
Orthodontic accessory bonding is considered one of the factors that most interferes in the expression of pre-adjusted appliances. Conventional direct or indirect techniques used fail to obtain the ideal position. The combination of novel technologies into indirect bonding digital methods offers new perspectives, seems to improve the accuracy related to the bonding position. The aim of the present study was to compare the accuracy of bonding orthodontic attachments in the digital environment in comparison with the direct procedure, considering the time of clinical experience of the professional. A total of 1120 artificial teeth, constituents of 40 identical models (20 solid sets + 20 digital sets), were equally distributed into two time intervals, between two groups of professionals Group I direct bonding (experienced clinicians); Group II direct bonding (post-graduate students); Group III virtual bonding (experienced clinicians); Group IV virtual bonding (post-graduate students). The differences in individual positions between the experimental and reference accessories were measured after three-dimensional superimposition of models in customized software. The analyses were conducted at a level of significance of 5%. The Mann-Whitney test showed significant differences between the mean values of the errors in the vertical dimensions (p = 0.029) and angulation (p = 0.041), between groups I and II, and in the vertical dimension (p =0.020) and angulation (p =0.019), between groups III and IV; the paired Wilcoxon test showed that the differences were significant in the vertical (p < 0.001) and horizontal (p < 0.001) dimensions, between groups I and III and in the vertical (p = 0.006) dimension, between groups II and IV; the Chi-square test showed significant differences in the prevalence of the deviations in all the dimensions (horizontal p < 0.002; vertical p < 0.001; angulation p < 0.001), with time of experience being significant in the horizontal dimension (p = 0.041). Both groups failed to obtain accuracy. The percentage of errors in virtual bonding was significantly lower than those in the linear dimensions (vertical and mesio-distal), and higher in angulation. The percentage of error of the professionals with a longer time of clinical experience was lower in the horizontal dimension. Early diagnosis of deviation in the bonding positions could be of direct benefit to both professional and patient, by foreseeing discrepancies that may lead to undesirable orthodontic movements.(AU)
Mots clés
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Appareils orthodontiques
/
Fils orthodontiques
/
Orthodontie correctrice
/
Collage dentaire
/
Brackets orthodontiques
/
Imagerie tridimensionnelle
/
Matériaux dentaires
/
Précision de la mesure dimensionnelle
Type d'étude:
Guideline
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
langue:
En
/
Pt
Année:
2018
Type:
Thesis