Eficiência de um sistema piloto utilizando áreas alagadas no pós-tratamento do lixiviado gerado no Aterro Sanitário de Curitiba, Curitiba, Paraná, Brasil / Efficiency of a pilot system using wetlands in the post-treatment of the leachate generated in the Curitiba Landfill, Curitiba, Paraná, Brazil
Eng. sanit. ambient
; Eng. sanit. ambient;23(3): 535-542, maio-jun. 2018. tab, graf
Article
de Pt
| LILACS
| ID: biblio-953258
Bibliothèque responsable:
BR1.1
RESUMO
RESUMO No Aterro Sanitário de Curitiba ocorre o pós-tratamento do lixiviado em áreas alagadas naturais. Para avaliar o papel das macrófitas nesse pós-tratamento, foi desenvolvido um sistema piloto. Dessa forma, o objetivo do presente estudo foi avaliar a eficiência do sistema piloto utilizado para o pós-tratamento do lixiviado desse aterro sanitário. O sistema foi construído com duas caixas d'água na primeira foi colocada a macrófita Echinochloa polystachya e na segunda, Eichhornia crassipes. O sistema operou em batelada e foi realizado um ciclo de sete dias. Para o monitoramento do sistema foram efetuadas coletas e análises do lixiviado, do substrato e das macrófitas. A eficiência do sistema no pós-tratamento do lixiviado foi de 72% para demanda bioquímica de oxigênio, 30% para demanda química de oxigênio, 76% para fósforo total e fósforo inorgânico, 38% para nitrato, 33% para nitrito, 58% para nitrogênio amonical, 44% para nitrogênio orgânico e 13% para zinco.
ABSTRACT
ABSTRACT In the Curitiba Landfill the post-treatment of the leachate occurs in natural wetlands. In order to evaluate the role of macrophytes in this post-treatment, it was developed a pilot system. Thus, the objective of this study was to evaluate the effectiveness of the pilot system in the post-treatment of the leachate in this landfill. The system was built with two water tanks the macrophyte Echinochloa polystachya was placed in the first one; and the Eichhornia crassipes was placed in the second one. The system operated in batch in a seven-day cycle. For monitoring the system, samples were collected, and analyses of the leachate, the substrate, and the macrophytes were performed. The efficiency of the system in the post-treatment of the leachate was 72% for biochemical oxygen demand, 30% for chemical oxygen demand, 76% for total phosphorus and inorganic phosphorus, 38% for nitrate, 33% for nitrite, 58% for ammoniacal nitrogen, 44% for organic nitrogen, and 13% for zinc.
Texte intégral:
1
Indice:
LILACS
Pays comme sujet:
America do sul
/
Brasil
langue:
Pt
Texte intégral:
Eng. sanit. ambient
Thème du journal:
SAUDE AMBIENTAL
/
SAUDE PUBLICA
Année:
2018
Type:
Article