Simplified micromethod for the HPLC measurement of diclofenac in plasma
Braz. j. med. biol. res
;
25(2): 125-8, 1992. ilus
Article
Dans Anglais
| LILACS
| ID: lil-109008
ABSTRACT
A simple and senmsitive micromethod based on HPLC is described for the measurement of diclofenac in 200 ul plasma. A single extraction with dichlormethane in acidic medium was an essential clean-up step. Diclofenac and its internal standard (cyclohexendiphenyl propionic acid) were eluted at 3.3 and 6.5 min from a 4-micron C18 reverse-phase column using a mobile phase consisting of 0.75 M sodium acetate buffer, pH 5.0, and acetonitrile (5545, v/v) at a flow rate of 0.9 ml/min with detection at 282 nm. The method, validated on the basis of parameters evaluated nfor the confidence limits of diclofenac measurements in spiked plasma, presented 1 ng/ml sensitivity, 10-10,000 ng/ml linearity, and 3.5% and 5.7% intra-and interassay precision, respectively. Peak plasma diclofenac levels ranging from 177 to 841 ng/ml and from 276 to 1008 ng/ml were obtained for two slow-release formulations. A wide range (1 ng/ml-3 ug/ml) was observed for plasma diclofenac levels of volunteers during a 24-h study period