Mensuração do volume de fluxo portal em pacientes esquistossomóticos: avaliação da reprodutibilidade do ultra-som Doppler / Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility
Radiol. bras
;
41(5): 305-308, set.-out. 2008. ilus, graf, tab
Article
Dans Anglais, Portugais
| LILACS
| ID: lil-496933
RESUMO
OBJETIVO:
Avaliar a reprodutibilidade do ultra-som Doppler na quantificação do volume de fluxo portal em pacientes esquistossomóticos.MATERIAIS E MÉTODOS:
Estudo prospectivo, transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica, submetidos a mensuração do fluxo portal pelo ultra-som Doppler por três observadores, de forma independente, sendo calculada a concordância entre estes, dois a dois, pelo coeficiente de correlação intraclasse, teste t-pareado e grau de linearidade de Pearson.RESULTADOS:
A concordância interobservador foi excelente. O coeficiente de correlação intraclasse variou entre 80,6 por cento e 93,0 por cento (IC a 95 por cento [65,3 por cento ; 95,8 por cento]), com coeficiente de correlação de Pearson variando entre 81,6 por cento e 92,7 por cento e sem diferença estatisticamente significante entre os observadores quanto à média do fluxo portal mensurado pelo ultra-som Doppler (p = 0,954 / 0,758 / 0,749).CONCLUSÃO:
O ultra-som Doppler é um método confiável para quantificar o fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador.ABSTRACT
OBJECTIVE:
To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. MATERIALS AND METHODOS Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient.RESULTS:
Interobserver agreement was excellent. Intraclass correlation ranged from 80.6 percent to 93.0 percent (IC at 95 percent [65.3 percent ; 95.8 percent]), with the Pearson's correlation coefficient ranging between 81.6 percent and 92.7 percent with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749).CONCLUSION:
Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement.
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Imagerie diagnostique
/
Reproductibilité des résultats
/
Hypertension portale
Type d'étude:
Etude diagnostique
/
Étude observationnelle
/
Étude de prévalence
/
Facteurs de risque
Limites du sujet:
Humains
Pays comme sujet:
Amérique du Sud
/
Brésil
langue:
Anglais
/
Portugais
Texte intégral:
Radiol. bras
Thème du journal:
Imagerie diagnostique
/
Radiologie
Année:
2008
Type:
Article
Pays d'affiliation:
Brésil
Institution/Pays d'affiliation:
Universidade Federal de São Paulo/BR
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS