Eficacia del reúso en hemodiálisis con dializadores de bajo y alto flujo / Efficacy of low and high flow dialyzer reuse in hemodialysis
Barrios Camba, Joanchín; Magrans Buch, Charles; Martínez Soto, Orquídea; Borrego Piñero, Julio.
  • Barrios Camba, Joanchín; Instituto de Nefrología Dr. Abelardo Buch López. La Habana. CU
  • Magrans Buch, Charles; Instituto de Nefrología Dr. Abelardo Buch López. La habana. CU
  • Martínez Soto, Orquídea; Instituto de Nefrología Dr. Abelardo Buch López. La habana. CU
  • Borrego Piñero, Julio; Instituto de Nefrología Dr. Abelardo Buch López. La habana. CU
Rev. cuba. med ; 47(1)ene.-mar. 2008. ilus, tab
Article Dans Espagnol | LILACS | ID: lil-499487
RESUMEN
El reúso de los dializadores constituye un problema de gran magnitud en nuestro país. Se realizó un estudio observacional, descriptivo y prospectivo para determinar la eficacia del reúso en cuanto a cantidad y calidad por dializador. Se estudiaron 8 pacientes en el Servicio de Hemodiálisis del Instituto de Nefrología durante 18 sem. Se utilizaron membranas de bajo y alto flujo, durante 2 etapas. El reúso fue automatizado utilizando como germicida ácido peracético. Se realizó aclaramiento de urea (Kdu) del dializador al 1, 6, 12, 15, 18, 21, 24, 27 usos, realizando un total de 432 hemodiálisis. Se observó que la media de los dializadores de bajo flujo fue de 11,05 y 14,07 para los de alto flujo. El Kdu de los dializadores de bajo flujo disminuyó 5,5 por ciento y 6,3 los de alto flujo. La dosis de diálisis (Kt/V) recibido se mantuvo en 1,2 a los 6 y 18 reúsos. Se concluyó que la media del reúso de ambos tipos de dializadores fue similar. El Kdu no se modifica con ambos tipos de membranas hasta el volumen residual aceptado. El reúso no modifica la dosis de diálisis recibida.
ABSTRACT
The dialyzer reuse is a problem of great magnitude in our country. An observational, descriptive and prospective study was conducted to determine the efficiency of reuse as regards quantity and quality per dialyzer. 8 patients were studied at the hemodialysis service of the Institute of Nephrology during 18 weeks. Low and high flow membranes were used in 2 stages. The reuse was automated, using peracetic acid as germicide. Urea was cleared (Kdu) from the dialyzer at 1, 6, 12, 15, 18, 21, 24, and 27 uses. 432 hemodialyses were performed in all. The mean of the low flow dialyzers was 11.05, and it was14.07 for those of high flow. The Kdu of the low flow dialyzers diminished 5.5 percent, whereas that of the high flow dialyzers dropped 6.3 percent. The dialysis dose (Kt/V) received was maintained in 1.2 at 6 and 18 reuses. It was concluded that the mean of reuse of both types of dialyzers was similar. The Kdu does not change with both types of membranes up to the accepted residual volume. The reuse does not modify the dialysis dose received.
Sujets)
Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dialyse rénale Type d'étude: Étude observationnelle Limites du sujet: Humains langue: Espagnol Texte intégral: Rev. cuba. med Thème du journal: Médicament Année: 2008 Type: Article Pays d'affiliation: Cuba Institution/Pays d'affiliation: Instituto de Nefrología Dr. Abelardo Buch López/CU

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Dialyse rénale Type d'étude: Étude observationnelle Limites du sujet: Humains langue: Espagnol Texte intégral: Rev. cuba. med Thème du journal: Médicament Année: 2008 Type: Article Pays d'affiliation: Cuba Institution/Pays d'affiliation: Instituto de Nefrología Dr. Abelardo Buch López/CU