Efeitos da compressão de dados JPEG na avaliação de lesões vasculares cerebrais isquêmicas de pequenos vasos em ressonância magnética / Effects of JPEG data compression on magnetic resonance imaging evaluation of small vessels ischemic lesions of the brain
Rev. imagem
; 28(1): 13-18, jan.-mar. 2006. ilus, graf, tab
Article
de Pt
| LILACS
| ID: lil-510361
Bibliothèque responsable:
BR1.2
RESUMO
OBJETIVO:
Estabelecer o limite máximo de compactação JPEG na qual não há comprometimento na análise quantitativa de lesões vasculares cerebrais isquêmicas de pequenos vasos em ressonância magnética. MATERIAL EMÉTODO:
Quinze imagens em DICOM foram convertidas para JPEG a taxas de compressão de 110 a 160 e avaliadas juntamente com as originais por três neurorradiologistas, que identificaram as lesões, tipo de contorno, morfologia e intensidade do sinal.RESULTADOS:
As lesões foram bem identificadas até a taxa de 130. Foram identificadas mais lesôes na taxa de 110 do que nas imagens originais. Morfologia e contornos foram bem avaliados até a taxa de 140. A compactação não alterou o sinal.CONCLUSÃO:
Foram avaliadas lesôes pequenas (até 2mm) e notamos que em todas as taxas de compactação o algoritmo gerou ruídos na imagem, que levaram os avaliadores a identificarem mais lesões nas imagens JPEG do que nas imagens originais DICOM, criando falso-positivos.ABSTRACT
OBJECTIVE:
To establish the maximum achievable JPEG compression ratio without affecting quantitative and qualitative magnetic resonance imaging analysis of isquemic lesions in small vessels of the brain. MATERIAL ANDMETHOD:
Fifteen DICOM images were converted to JPEG with a compression ratio of 110 to 160 and were assessed together with the original images by three neuroradiologists. The number, morphology, edges and signal intensity of the lesions were analyzed.RESULTS:
Lesions were properly identified up to a 130 ratio. More lesions were identified with a 110 ratio then in the original images. Morphology and edges were properly evaluated up to a 140 ratio. Compression did not affect signal.CONCLUSION:
Small lesions were identified (<2mm) and in all compression ratios JPEG algorithm generated image noise that misled observers to identify more lesions in JPEG images then in DICOM images, thus generating false-positive results.
Recherche sur Google
Indice:
LILACS
Sujet Principal:
Systèmes d'information
/
Imagerie par résonance magnétique
/
Angiopathies intracrâniennes
/
Mémorisation et recherche des informations
/
Compression de données
/
Analyse de Fourier
Type d'étude:
Diagnostic_studies
/
Evaluation_studies
/
Prognostic_studies
/
Qualitative_research
Limites du sujet:
Humans
langue:
Pt
Texte intégral:
Rev. imagem
Thème du journal:
MEDICINA NUCLEAR
/
RADIOTERAPIA
Année:
2006
Type:
Article