RESUMO

OBJETIVO:

Analisar, por meio de um modelo computacional da região ocular, as características da distribuição da dose utilizando placas contendo iodo-125 e rutênio/ródio-106.

MATERIAIS E MÉTODOS:

Foi utilizado um modelo computacional de voxels da região ocular incluindo os diversos tecidos, com a placa posicionada sobre a esclera. O código Monte Carlo foi utilizado para simular a irradiação. A distribuição da dose é apresentada por curvas de isodoses.

RESULTADOS:

As simulações computacionais apresentam a distribuição da dose no interior do bulbo e nas estruturas externas. Os resultados permitem comparar a distribuição espacial das doses geradas por partículas beta e por fótons. As simulações mostram que a aplicação de sementes de iodo-125 implica alta dose no cristalino, enquanto o rutênio/ródio-106 produz alta dose na superfície da esclera.

CONCLUSÃO:

A dose no cristalino depende da espessura do tumor, da posição e do diâmetro da placa, e do radionuclídeo utilizado. No presente estudo, a fonte de rutênio/ródio-106 é recomendada para tumores de dimensões reduzidas. A irradiação com iodo-125 gera doses maiores no cristalino do que a irradiação com rutênio/ródio-106. O valor máximo de dose no cristalino corresponde a 12,75 por cento do valor máximo de dose com iodo-125 e apenas 0,005 por cento para rutênio/ródio-106.
ABSTRACT

OBJECTIVE:

To analyze dose distribution utilizing plaques with iodine-125 and ruthenium/rhodium-106 in a computational model of the ocular region. MATERIALS AND

METHODS:

A voxel-based computational model including the different tissues of the ocular region was utilized with the plaque positioned on the sclera. The Monte Carlo code was utilized for simulating irradiation. The dose distribution is demonstrated by isodoses curves.

RESULTS:

Computational simulations demonstrate the dose distribution inside the ocular bulb as well as in adjacent outside structures. The results have allowed the authors to compare the spatial distribution of doses generated by beta particles and photons. The simulations demonstrated that the utilization of iodine 125 seeds implies a high dose to the crystalline lens, while ruthenium/rhodium-106 results in high dose on the sclera surface.

CONCLUSION:

The dose to the crystalline lens depends on the tumor position and thickness, the plaque diameter, and the radionuclide utilized. In the present study, the ruthenium/rhodium-106 source is recommended for low tumor thickness. Irradiation with iodine-125 results in higher doses to the crystalline lens than irradiation with ruthenium/rhodium-106. The maximum value for dose to the crystalline lens corresponds to 12.75 percent of the maximum dose with iodine-125 and only 0.005 percent for ruthenium/rhodium-106.

Texte intégral: Disponible Indice: LILAS (Amériques) Type d'étude: Étude pronostique langue: Portugais Texte intégral: Radiol. bras Thème du journal: Imagerie diagnostique / Radiologie Année: 2009 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Universidade Federal de Minas Gerais/BR

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: LILAS (Amériques) Type d'étude: Étude pronostique langue: Portugais Texte intégral: Radiol. bras Thème du journal: Imagerie diagnostique / Radiologie Année: 2009 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Universidade Federal de Minas Gerais/BR