Comparação entre ergômetros específico e convencionais na determinação da capacidade aeróbia de mesatenistas / Comparison between specific and conventional ergometers in the aerobic capacity determination in table tennis players
Rev. bras. med. esporte
;
15(3): 204-208, maio-jun. 2009. graf, tab
Article
Dans Portugais
| LILACS
| ID: lil-517537
RESUMO
O objetivo deste estudo foi verificar a necessidade de utilizar protocolo específico para avaliar a capacidade aeróbia de mesatenistas, comparando os testes aplicados em ergômetro específico com ergômetros convencionais. Para isso, nove mesatenistas foram os participantes do estudo (18,22 ± 2,33 anos; altura de 1,76 ± 0,09m; massa corporal de 67,36 ± 10,03kg; gordura corporal de 14,74 ± 6,69 por cento; e índice de massa corporal (IMC) de 21,69 ± 2,71kg/m²). Foram aplicados os testes de lactato mínimo, realizados no ergômetro de braço (LACmin braço) e no cicloergômetro (LACmin ciclo) (ergômetros convencionais) e o teste de limiar anaeróbio em procedimento específico para o tênis de mesa (LAn espec) utilizando um lançador de bolas mecânico como ergômetro. Como procedimentos estatísticos foram utilizados o teste de análise de variância (ANOVA) one way e o teste de correlação produto-momento, com nível de significância de 5 por cento. O LAn espec (48,11 ± 6,82 bolas.min-1) não foi significativamente correlacionado com a intensidade de LACmin braço (91,94 ± 11,51W) (r = 0,18; p = 0,72); e apresentou correlação negativa com a intensidade de LACmin ciclo (157,97 ± 12,51W) (r = - 0,80; p = 0,02). Desse modo, os resultados encontrados no estudo levam a concluir que existe necessidade do uso de protocolo específico para mensurar a capacidade aeróbia no tênis de mesa.
ABSTRACT
The aim of this study was to verify the necessity to use a specific protocol for evaluating the aerobic capacity in table tennis players, comparing the tests applied in conventional ergometers with test applied in specific ergometer. Nine table tennis players were participants in the study (18.22 ± 2.33 years; 1.76 ± 0.09 m of height; 67.36 ± 10.03 Kg of body mass; 14.74 ± 6.69 percent of fat mass and 21.69 ± 2.71 Kg/m² of body mass index). The participants performed lactate minimum tests in the arm ergometer and cycle ergometer; in addition to incremental test in specific ergometer for determination of the anaerobic threshold (AnTspec) through visual inspection. Statistical procedures used Analysis of Variance test (one-way ANOVA) and the Pearson correlation test, with level of significance of 5 percent. There was not significant correlation between the AnTspec (48.11 ± 6.82 shots.min-1) and the lactate minimum intensity obtained in arm ergometry (91.94 ± 11.51 W) (r=0.18; p=0.72). The lactate minimum intensity in cycle ergometer (157.97 ± 12.51 W) presented significant correlation with the AnTspec (r=-0.80; p=0.02), but a negative correlation was verified. Therefore, a specific protocol is needed for measuring the aerobic capacity in table tennis.
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Sports
/
Seuil anaérobie
/
Acide lactique
Type d'étude:
Guide de pratique
Limites du sujet:
Humains
/
Mâle
langue:
Portugais
Texte intégral:
Rev. bras. med. esporte
Thème du journal:
Médecine du sport
Année:
2009
Type:
Article
Pays d'affiliation:
Brésil
Institution/Pays d'affiliation:
Universidade Estadual Paulista/BR
/
Universidade Federal de Mato Grosso do Sul/BR
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS