Osteossíntese das fraturas da extremidade proximal do úmero com sistema de placa de ângulo fixo com parafusos bloqueados: técnica e resultados / Osteosynthesis of proximal humeral end fractures with fixed angle plate and locking screws: technique and results
Rev. bras. ortop
;
44(2): 106-111, mar.-abr. 2009. ilus, tab
Article
Dans Portugais
| LILACS
| ID: lil-517597
RESUMO
OBJETIVO:
Descrever os resultados do tratamento cirúrgico das fraturas da extremidade proximal do úmero com a placa de sistema bloqueado Philos.MÉTODOS:
Entre março de 2003 e outubro de 2004 foram avaliados, de forma prospectiva, 24 de 26 pacientes com fratura da extremidade proximal do úmero tratados com a placa Philos. A média de seguimento foi de 12 meses e da idade dos pacientes, de 57 anos. Seis pacientes tinham fraturas em quatro partes, 11 em três partes e nove em duas partes. A avaliação clínica foi feita por meio dos critérios da University of California at Los Angeles (UCLA).RESULTADOS:
A média do escore da UCLA foi de 30 pontos (17-35). Todas as fraturas consolidaram. Em três pacientes a fratura consolidou em varo. Nesses, o índice da UCLA médio foi de 27 pontos.CONCLUSÃO:
A osteossíntese com a placa Philos permite fixação estável com bom resultado funcional.ABSTRACT
OBJECTIVE:
Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system.METHOD:
Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria.RESULTS:
The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points.CONCLUSION:
Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome.
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Ostéosynthèse interne
/
Fractures de l'humérus
Type d'étude:
Etude d'étiologie
/
Etude d'incidence
/
Étude observationnelle
/
Facteurs de risque
Limites du sujet:
Adulte
/
Adulte très âgé
/
Aged80
/
Femelle
/
Humains
/
Mâle
langue:
Portugais
Texte intégral:
Rev. bras. ortop
Thème du journal:
Orthopédie
Année:
2009
Type:
Article
Pays d'affiliation:
Brésil
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS