Your browser doesn't support javascript.
loading
Avaliação do ruído em Unidades de Terapia Intensiva / Noise Assessment in Intensive Care Units
Macedo, Ivan Senis Cardoso; Mateus, Daniela Cunha; Costa, Eduardo De Martin Guedes C; Asprino, Ana Cristina Lanfranchi; Lourenço, Edmir Américo.
  • Macedo, Ivan Senis Cardoso; s.af
  • Mateus, Daniela Cunha; Faculdade de Medicina de Jundiaí.
  • Costa, Eduardo De Martin Guedes C; Faculdade de Medicina de Jundiaí.
  • Asprino, Ana Cristina Lanfranchi; Faculdade de Medicina de Jundiaí.
  • Lourenço, Edmir Américo; Faculdade de Medicina de Jundiaí.
Braz. j. otorhinolaryngol. (Impr.) ; 75(6): 844-846, nov.-dez. 2009.
Article Dans Portugais | LILACS | ID: lil-539381
RESUMO
As Unidades de Terapia Intensiva são ambientes em que existem inúmeras fontes geradoras de ruído. Recomenda-se, em diferentes ambientes hospitalares, níveis de pressão sonora entre 35 e 45db(A).

OBJETIVO:

Realizar mensuração dos níveis de pressão sonora de três Unidades de Terapia Intensiva de um hospital em Jundiaí, Estado de São Paulo, Brasil. FORMA DE ESTUDO Observacional. MATERIAL E

MÉTODOS:

Foi utilizado decibelímetro Minipa modelo MSL1532C (USA) de acordo com as normas da Associação Brasileira de Normas Técnicas (NBR 10151), para medir os níveis sonoros nas Unidades de Terapia Intensiva em períodos variados, isto é, manhã, tarde e noite em horários de pico de atividade.

RESULTADOS:

Os valores encontrados durante as aferições dos níveis de pressão sonora foram de 64.1dB(A) na Primeira Unidade de Terapia Intensiva, 58.9 dB(A) na Unidade Coronariana e 64dB(A) na Segunda Unidade de Terapia Intensiva.

CONCLUSÃO:

Níveis elevados de pressão sonora em Unidades de Terapia Intensiva ainda significam um problema importante na morbidade dos pacientes de tais unidades de atendimento à saúde. Nenhuma das três UTI apresentaram níveis maiores que 85dB, demonstrando que não há risco ocupacional para as equipes de saúde nos ambientes pesquisados.
ABSTRACT
Intensive Care Units are environments with numerous noise sources. In different hospital environments it is recommended to have a sound pressure level between 35 and 45db(A).

AIM:

To measure the sound pressure levels in three ICU at a hospital in Jundiaí, State of São Paulo, Brazil. STUDY

DESIGN:

Observational. MATERIALS AND

METHODS:

we used a Minipa model MSL1532C (USA) sound meter, according to the Brazilian Technical Standards (NBR 10151), in order to measure sound levels in the ICUs at different moments, that is, the morning, afternoon and night at peak times of activity.

RESULTS:

The values found during the checking of the sound pressure levels were 64.1dB (A) in the First ICU, 58.9 dB (A) in the Coronary Unit and 64dB (A) in the second ICU.

CONCLUSION:

High sound pressure levels in ICU still mean an important health-related problem for patients in these units. None of the three ICU pad levels above 85dB, showing that there is no occupational risk for the health care teams in the environments studied.
Sujets)

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Environnement d'établissement de santé / Unités de soins intensifs / Bruit Type d'étude: Guide de pratique / Étude observationnelle Limites du sujet: Humains Pays comme sujet: Amérique du Sud / Brésil langue: Portugais Texte intégral: Braz. j. otorhinolaryngol. (Impr.) Thème du journal: Otolaryngologie Année: 2009 Type: Article Pays d'affiliation: Brésil

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Environnement d'établissement de santé / Unités de soins intensifs / Bruit Type d'étude: Guide de pratique / Étude observationnelle Limites du sujet: Humains Pays comme sujet: Amérique du Sud / Brésil langue: Portugais Texte intégral: Braz. j. otorhinolaryngol. (Impr.) Thème du journal: Otolaryngologie Année: 2009 Type: Article Pays d'affiliation: Brésil