Your browser doesn't support javascript.
loading
Avaliação biomecânica de implantes imediatos com carga imediata: análise 3D em elementos finitos / Biomechanical evaluation of immediately placed implants: CT-based 3D finite element analysis
Pessoa, Roberto Sales e; Muraru, Luiza; Vaz, Luis Geraldo; Marcantonio Júnior, Elcio; Sloten, Jos Vander; Oliveira, Sérgio Ricardo de; Jaecques, Siegfried V. N.
  • Pessoa, Roberto Sales e; Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara. Araraquara. BR
  • Muraru, Luiza; Katholiee Universiteit Leuven. Leuven. BE
  • Vaz, Luis Geraldo; Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara. Araraquara. BR
  • Marcantonio Júnior, Elcio; Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara. Araraquara. BR
  • Sloten, Jos Vander; Katholiee Universiteit Leuven. Leuven. BE
  • Oliveira, Sérgio Ricardo de; Instituto de Pesquisa e Ensino em Saúde. Uberlândia. BR
  • Jaecques, Siegfried V. N; Katholiee Universiteit Leuven. Leuven. BE
Innov. implant. j., biomater. esthet. (Impr.) ; 4(2): 10-16, maio-ago. 2009. ilus
Article Dans Portugais | LILACS, BBO | ID: lil-561079
RESUMO

Objetivo:

o objetivo do presente estudo foi analisar o ambiente biomecânico de implantes imediatos com carga imediata, comparando 3 diferentes magnitudes de carga. Material e

Métodos:

um modelo em elementos finitos de um incisivo central superior contendo um implante cônico de 13 mm de comprimento e 4,5 mm de plataforma, hexágono interno, foi construído. Elementos de contato friccional foram utilizados para simular as interfaces entre o osso, implante, abutment e parafuso do abutment. Foram aplicadas forças de 50, 100 e 200 N na extremidade superior do abutment. Os dados para a deformação equivalente no osso, as tensões equivalentes no parafuso, deslocamento relativo osso-implante e gap do abutment foram calculados. Resultados/

Conclusão:

a magnitude das cargas aplicadas sobre os implantes imediatos com carga imediata influenciam significativamente o ambiente biomecânico deste protocolo.
ABSTRACT

Objective:

the purpose of the present study was to evaluate the biomechanical environment of immediately placed implants, by comparing three different loading magnitudes. Material and

Methods:

a CT-based finite element model of an upper central incisor extraction socket was constructed containing a conical internal hex 13-mm implant. Frictional contact elements were used in the bone, implant, abutment and abutment screw interfaces. Forces of 50, 100 and 200 N were applied on the superior central region of the abutment. Data for the peak equivalent strain in the bone, peak Von Mises stress in the abutment screw, bone-to-implant relative displacement and abutment gap were calculated. Results/

Conclusion:

the loading magnitudes applied over the implants are capable to greatly influence the biomechanical environment in immediately placed protocol.
Sujets)

Recherche sur Google
Indice: LILAS (Amériques) Sujet Principal: Phénomènes biomécaniques / Implants dentaires / Ostéo-intégration langue: Portugais Texte intégral: Innov. implant. j., biomater. esthet. (Impr.) Thème du journal: Chirurgie générale / Dentisterie / Orthodontie Année: 2009 Type: Article Pays d'affiliation: Belgique / Brésil Institution/Pays d'affiliation: Instituto de Pesquisa e Ensino em Saúde/BR / Katholiee Universiteit Leuven/BE / Universidade Estadual Paulista/BR

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Recherche sur Google
Indice: LILAS (Amériques) Sujet Principal: Phénomènes biomécaniques / Implants dentaires / Ostéo-intégration langue: Portugais Texte intégral: Innov. implant. j., biomater. esthet. (Impr.) Thème du journal: Chirurgie générale / Dentisterie / Orthodontie Année: 2009 Type: Article Pays d'affiliation: Belgique / Brésil Institution/Pays d'affiliation: Instituto de Pesquisa e Ensino em Saúde/BR / Katholiee Universiteit Leuven/BE / Universidade Estadual Paulista/BR