Contaminação bacteriana em concentrados plaquetários: identificação, perfil de sensibilidade aos antimicrobianos e sepse associada à transfusão / Bacterial contamination on platelet concentrates: identification, antimicrobial susceptibility profile and transfusion-related sepsis
Rev. Soc. Bras. Med. Trop
; Rev. Soc. Bras. Med. Trop;43(6): 682-685, Nov.-Dec. 2010. tab
Article
de Pt
| LILACS
| ID: lil-569431
Bibliothèque responsable:
BR1.1
RESUMO
INTRODUÇÃO:
Devido à sepse bacteriana associada à transfusão de concentrados plaquetários (CPs) ter sérias consequências clínicas para os pacientes, alguns procedimentos têm sido incorporados na preparação e no controle de qualidade dos componentes sanguíneos para reduzir o risco da contaminação bacteriana. Este artigo descreve a prevalência da contaminação bacteriana dos CPs que foram transfundidos, o espectro bacteriano detectado com seu perfil de sensibilidade aos antimicrobianos e as reações transfusionais nos receptores.MÉTODOS:
Um total de 292 CPs (278 randômicos e 14 por aférese), proveniente do Hemocentro do Estado do Rio Grande do Sul (HEMORGS) de Santa Maria foi testado. As quantidades de 100μL e 200μL foram coletadas da porção tubular da bolsa de plaquetas e semeadas utilizando dois tipos de metodologias.RESULTADOS:
Em cinco unidades(1,7 por cento; 5/292) foram isoladas bactérias pela metodologia qualitativa e apenas uma pela quantitativa. Staphylococcus epidermidis foi o microrganismo identificado em todas as amostras. Dois pacientes apresentaram sepse associada à transfusão com desfecho fatal.CONCLUSÕES:
A contaminação bacteriana pelas transfusões de CPs constitui-se num importante problema de saúde pública devido a sua associação com altas taxas de morbidade e mortalidade. Neste estudo, somente microrganismos gram-positivos foram isolados sendo que nenhuma amostra obtida por aférese apresentou contaminação.ABSTRACT
INTRODUCTION:
Bacterial sepsis associated with the transfusion of platelet concentrates (PCs) results in serious clinical implications for patients. Given these implications, certain procedures have been integrated into the preparation and quality control of blood components to reduce the risk of bacterial contamination. This article describes the prevalence of bacterial contamination on transfused PCs, the bacterial spectrum detected and their antimicrobial susceptibility profile and transfusion reactions in receptors.METHODS:
A total of 292 PCs (278 random and 14 per apheresis) from the Blood Center of the State of Rio Grande do Sul (HEMORGS), located in the city of Santa Maria, were tested. Quantities of 100μL and 200μL were collected from platelet bag tubing and seeded using two methodologies.RESULTS:
Using the qualitative methodology, bacteria were isolated in five units (1.7 percent; 5/292), while only one was isolated using the quantitative methodology. Staphylococcus epidermidis was the microorganism identified in all samples. Two patients died of transfusion-related sepsis.CONCLUSIONS:
Bacterial contamination due to PC transfusion is considered a major public health problem due to its association with high rates of morbidity and mortality. In this study only gram-positive microorganisms were isolated and none of the samples obtained by apheresis presented contamination.Mots clés
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Infections à staphylocoques
/
Staphylococcus epidermidis
/
Plaquettes
/
Transfusion de plaquettes
/
Sepsie
/
Antibactériens
Type d'étude:
Clinical_trials
/
Diagnostic_studies
/
Qualitative_research
/
Risk_factors_studies
Limites du sujet:
Adult
/
Humans
/
Newborn
langue:
Pt
Texte intégral:
Rev. Soc. Bras. Med. Trop
Thème du journal:
MEDICINA TROPICAL
Année:
2010
Type:
Article