Your browser doesn't support javascript.
loading
Distribuição das tensões relacionadas ao uso de retentores em dentes tratados endodonticamente utilizando o método dos elementos finitos / Stress distribution related to the use of retainers in endodontically treated teeth using the finite element method
Ferreira, Caroline Baptista; Graça, Luiz Felipe Almeida; Bittencourt, Rafael Cotias; Vallado, Sandro Thomé; Gouvêa, Cresus Vinicius Depes de; Oliveira, Henrique Eduardo.
  • Ferreira, Caroline Baptista; s.af
  • Graça, Luiz Felipe Almeida; s.af
  • Bittencourt, Rafael Cotias; Universidade Federal Fluminense. Niterói. BR
  • Vallado, Sandro Thomé; s.af
  • Gouvêa, Cresus Vinicius Depes de; Universidade Federal Fluminense. Faculdade de Odontologia. Departamento de Odontotécnica. Niterói. BR
  • Oliveira, Henrique Eduardo; Universidade Federal Fluminense. Niterói. BR
Article Dans Portugais | LILACS, BBO | ID: lil-663213
RESUMO
A restauração dos dentes tratados endodonticamente, com grande fragilidade de suas estruturas, traz dúvidas ao clínico quanto à melhor forma de atuar nesses elementos. Os retentores intrarradiculares, sejam núcleos metálicos fundidos ou pré-fabricados, são geralmente necessários para a restauração destes elementos. Cada um desses materiais imprime uma força diferente nas estruturas adjacentes, sendo o entendimento destas uma necessidade para a melhor escolha e aplicação clínica do retentor.

Objetivo:

A proposta do presente trabalho é analisar e avaliar a distribuição de tensões no complexo dente-periodonto pelo método dos elementos finitos bidimensional com a utilização de diferentes tipos de retentores.

Método:

Este estudo tem por base modelos matemáticos de um canino superior tratado endodonticamente com a utilização de retentores intrarradiculares metálicos fundidos em NiCr, metálicos pré-fabricados em titânio. Os modelos foram submetidos a uma carga de 100 N por palatina em um ângulo de 45º. A análise e avaliação das tensões foram realizadas para cada um dos modelos e seus diferentes tipos de pinos.

Resultados:

A maior concentração de tensões se deu com o uso do pino metálico pré-fabricado de titânio, com valores de tração que oscilam entre 1.207 MPa a 4.878 MPa e de compressão entre -9.806 MPa a -2.464 MPa. O pino metálico fundido imprimiu tensões de menores valores, mais homogêneas e uniformes, tendo seus valores de tração variando de 1.287 MPa a 4.919 Mpa e seus valores de compressão variando de -9.607 MPa a 2.344 Mpa.

Conclusão:

Os pinos intrarradiculares metálicos pré-fabricados de titânio geram forte estresse no sistema dente-periodonto, sendo o menos indicado clinicamente. O mais indicado para uso clínico foi o pino metálico fundido, cuja tensão se manifestou de maneira mais uniforme no elemento dentário.
ABSTRACT
The restoration of endodontically treated teeth with great structure fragility challenges the clinician about the best way to proceed on these elements. The use of intracanal retainers, either post and core systems of prefabricated posts, is usually necessary to restore this kind of teeth. Each one of these materials exerts a different force on the adjacent structures and understanding these forces is mandatory for a better choice and clinical application of intracanal retainers.

Objective:

The purpose of this study was to analyze and evaluate the stress distribution in the tooth-periodontium complex by the two-dimensional finite element method, using different types of retainers.

Methods:

This study was based on mathematical models of an endodontically treated maxillary canine, using a NiCr cast intracanal posts and a prefabricated titanium post. The models were subjected to a 100 N load directed palatally at a 45º angle. The strains for each of the models and different types of post were analyzed and evaluated.

Results:

The highest stress concentration occurred with the use of the prefabricated titanium post, with traction values ranging from 1207 MPa to 4878 MPa and compression values between -9806 and -2464 MPa. The NiCr cast post exhibited lower tension values, with a more homogeneous and uniform distribution, traction values ranging from 1287 MPa to 4919 MPa and compression values ranging from -9607 MPa to 2344 MPa.

Conclusion:

Prefabricated titanium intraradicular posts induced strong stress to the tooth-periodontium complex and is less indicated clinically. The metal cast post appears more adequate cast for clinical use, as the resulting tension was distributed more uniformly along the tooth.
Sujets)

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Phénomènes biomécaniques / Restauration coronoradiculaire / Tenons dentinaires / Endodontie / Phénomènes physiques langue: Portugais Texte intégral: Pesqui. bras. odontopediatria clín. integr Thème du journal: Dentisterie Année: 2012 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Universidade Federal Fluminense/BR

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Phénomènes biomécaniques / Restauration coronoradiculaire / Tenons dentinaires / Endodontie / Phénomènes physiques langue: Portugais Texte intégral: Pesqui. bras. odontopediatria clín. integr Thème du journal: Dentisterie Année: 2012 Type: Article Pays d'affiliation: Brésil Institution/Pays d'affiliation: Universidade Federal Fluminense/BR