Your browser doesn't support javascript.
loading
Estudio de confiabilidad de la prueba de sialometría para flujo no estimulado en sujetos adultos clínicamente sanos / Study of reliability of the sialometry test for non-stimulated flow in clinically healthy adult individuals
Aitken Saavedra, J; Maturana Ramírez, A; Morales Bozo, I; Hernández Ríos, M; Rojas-Alcayaga, G.
  • Aitken Saavedra, J; Universidad de Chile. Facultad de Odontología. Departamento de Patología y Medicina Oral. CL
  • Maturana Ramírez, A; Universidad de Chile. Facultad de Odontología. Departamento de Patología y Medicina Oral. CL
  • Morales Bozo, I; Universidad de Chile. Facultad de Odontología. Departamento de Ciencias Químicas y Físicas. CL
  • Hernández Ríos, M; Universidad de Chile. Facultad de Odontología. Departamento de Patología y Medicina Oral. CL
  • Rojas-Alcayaga, G; Universidad de Chile. Facultad de Odontología. Departamento de Patología y Medicina Oral. CL
Article Dans Espagnol | LILACS | ID: lil-673083
RESUMEN

Introducción:

En personas sanas, la velocidad de flujo salival o sialometría (VFS) puede afectarse por la edad, género y ritmo circadiano. No existe evidencia de la reproducibilidad de VFS no estimulada determinada en 5 minutos, en distintos momentos del día en un mismo individuo.

Objetivos:

Determinar confiabilidad de VFS no estimulada medida en 5 minutos, reproducibilidad en el tiempo y relación con rango etario y género.

Metodología:

Se determinó VFS durante 15 minutos en 42 individuos clínicamente sanos, con una mediana de 45.5 (30-65) años, entre 9 y 11 AM durante dos mañanas y entre 3 y 5 PM durante la tarde del segundo día de medición. La saliva se colectó en tubos separados durante 5 minutos y durante los 10 minutos restantes. El peso de las muestras fue expresado en ml/min. Los valores entre los grupos de estudio, se compararon mediante test t de Student, ANOVA y coeficiente de correlación de Spearman.

Resultados:

VFS promedio fue de 0.623 +/- 0.329 y de 0.551 +/- 0.289 a los 5 y 15 minutos respectivamente (p=0.001). VFS fue mayor en hombres a los 5 y 15 minutos (p=0.001). VFS en mujeres, disminuyó al aumentar la edad. No hubo diferencias en VFS a los 5 minutos (p=0.375) y a los 15 minutos (p=0.825), en distintos días y momentos del día, en un mismo individuo.

Conclusión:

VFS colectada durante 5 minutos, en un mismo individuo, presenta valores constantes en distintos días y momentos del día.
ABSTRACT

Introduction:

In healthy persons, the salivary flow rate (VFS) or sialometry can be affected by the age, the gender and the circadian rhythm. There is no evidence of the reproducibility of the non-stimulated VFS determined in 5 minutes, in different moments of the day in the same individual.

Aim:

To determine the reliability of the non-stimulated VFS measured in 5 minutes, its reproducibility over time and its relation with the age range and the gender.

Methodology:

VFS was determined for 15 minutes in 42 clinically healthy individuals, with a median age of 45.5 (30-65), between 9 and 11 AM in two mornings and between 3 and 5 PM in the evening of the second day of measurement. The saliva was collected in 2 separated pipes, one for the first 5 minutes and one for the 10 remaining minutes. The weight of the samples was expressed in ml/min. The values between the groups of study were compared by means of the Student’s t-test, ANOVA and the Spearman’s correlation coefficient.

Results:

The average VFS was of 0.623 +/- 0.329 and of 0.551 +/- 0.289 after 5 and 15 minutes respectively (p=0.001). VFS was higher in men after 5 and 15 minutes (p=0.001). VFS in women diminished as the age increased. There were no differences in VFS after 5 minutes (p=0.375) and after 15 minutes (p=0.825), in different days and moments of the day, in the same individual.

Conclusion:

VFS collected for 5 minutes in the same individual presents constant values in the different days and moments of the day.
Sujets)


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Salive / Débit sécrétoire Limites du sujet: Adulte / Femelle / Humains / Mâle langue: Espagnol Texte intégral: Rev. clín. periodoncia implantol. rehabil. oral (Impr.) Thème du journal: Dentisterie Année: 2013 Type: Article Pays d'affiliation: Chili Institution/Pays d'affiliation: Universidad de Chile/CL

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Salive / Débit sécrétoire Limites du sujet: Adulte / Femelle / Humains / Mâle langue: Espagnol Texte intégral: Rev. clín. periodoncia implantol. rehabil. oral (Impr.) Thème du journal: Dentisterie Année: 2013 Type: Article Pays d'affiliation: Chili Institution/Pays d'affiliation: Universidad de Chile/CL