Your browser doesn't support javascript.
loading
Vibroacoustography for the assessment of total hip arthroplasty
Kamimura, Hermes A.S.; Wang, Liao; Carneiro, Antonio A.O.; Kinnick, Randall R.; An, Kai-Nan; Fatemi, Mostafa.
  • Kamimura, Hermes A.S.; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
  • Wang, Liao; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
  • Carneiro, Antonio A.O.; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
  • Kinnick, Randall R.; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
  • An, Kai-Nan; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
  • Fatemi, Mostafa; Mayo Clinic. College of Medicine. Department of Physiology and Biomedical Engineering. Rochester. US
Clinics ; 68(4): 463-468, abr. 2013. graf
Article Dans Anglais | LILACS | ID: lil-674233
ABSTRACT

OBJECTIVES:

This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation.

METHODS:

A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system.

RESULTS:

The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements.

CONCLUSION:

Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications. .
Sujets)


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Arthroplastie prothétique de hanche / Imagerie d'élasticité tissulaire Type d'étude: Etude diagnostique / Étude pronostique Limites du sujet: Humains langue: Anglais Texte intégral: Clinics Thème du journal: Médicament Année: 2013 Type: Article / descriptif de projet Pays d'affiliation: États-Unis d'Amérique Institution/Pays d'affiliation: Mayo Clinic/US

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS


Texte intégral: Disponible Indice: LILAS (Amériques) Sujet Principal: Arthroplastie prothétique de hanche / Imagerie d'élasticité tissulaire Type d'étude: Etude diagnostique / Étude pronostique Limites du sujet: Humains langue: Anglais Texte intégral: Clinics Thème du journal: Médicament Année: 2013 Type: Article / descriptif de projet Pays d'affiliation: États-Unis d'Amérique Institution/Pays d'affiliation: Mayo Clinic/US