Características in vivo del epitelio corneal versus magnitud del defecto refractivo, posterior a tratamiento con láser de excímeros / In vivo characteristics of the corneal epithelium vs size of the refractive error after Excimer laser treatment
Rev. cuba. oftalmol
;
26(2): 208-214, mayo.-ago. 2013.
Article
Dans Espagnol
| LILACS
| ID: lil-695031
RESUMEN
Objetivo:
describir las características in vivo del epitelio corneal y su relación con la magnitud del defecto refractivo tratado posterior al tratamiento quirúrgico de LASIK.Método:
estudio descriptivo, prospectivo-longitudinal con 24 pacientes 48 ojos con astigmatismo miópico intervenidos con el ESIRIS Schwind-Alemania por la técnica quirúrgica LASIK con microquerátomo pendular. Se analizaron los resultados a partir de técnicas de estadística descriptiva. Se utilizó el microscopio confocal ConfoScan 4 de NIDEK para la obtención y estudio de las imágenes in vivo de tejido corneal.Resultados:
el grosor epitelial central medio en el preoperatorio fue 34,7 mm, a los 7 días del posoperatorio hubo un incremento del 36 por ciento en pacientes con defectos refractivos inferiores a 4D y un incremento del 44 por ciento en pacientes con defectos refractivos de 4 D o más. El promedio de densidad de células del epitelio basal a los 7 días fue de 5 098,3±1 654 células/mm², tuvo variaciones mínimas inferiores a la unidad porcentual durante la etapa de estudio.Conclusiones:
existió incremento del grosor epitelial posterior a LASIK que fue superior en defectos refractivos mayores de 4 dioptrías. La densidad celular del epitelio basal no tuvo variaciones significativas y fue independiente a la magnitud del defecto refractivo tratadoABSTRACT
Objective:
to describe the in vivo characteristics of the corneal epithelium and their association with the size of the treated refractive defect after LASIK.Methods:
a prospective, longitudinal and descriptive study of 24 patients (48 eyes) with myopic astigmatism, who were operated on by using ESIRIS (Schwind-Germany) and LASIK technique with pendular microketatome. Summary statistic techniques served to analyze results. NIDEK´s ConfoScan 4 microscope was used to obtain and to study in vivo corneal tissue images.Results:
mean central epithelial thickness measured in the preoperative stage was 34.7 mm, but increased by 36 percent seven days after surgery in patients with refractive defects fewer than 4D and by 44 percent in patients with refractive defects equal to or over 4D. The average cell density of the basal epithelium 7 days postoperatively was 5 098.3±1 654 cell/mm² and showed minimal changes below 1 percent during the study period.Conclusions:
the central corneal epithelium thickness increased after LASIK surgery and it was higher in refractive defects over 4D. Cell density of the basal epithelium did not show significant changes and was not associated to the size of the treated refractive defect
Texte intégral:
Disponible
Indice:
LILAS (Amériques)
Sujet Principal:
Troubles de la réfraction oculaire
/
Astigmatisme
/
Chirurgie de la cornée par laser
/
Lasers à excimères
Type d'étude:
Étude observationnelle
/
Facteurs de risque
Limites du sujet:
Femelle
/
Humains
/
Mâle
langue:
Espagnol
Texte intégral:
Rev. cuba. oftalmol
Thème du journal:
Ophtalmologie
Année:
2013
Type:
Article
Pays d'affiliation:
Cuba
Institution/Pays d'affiliation:
Centro Oftalmológico de Pinar del Río/CU
/
Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS