Your browser doesn't support javascript.
loading
Taxa de contaminação de testes hematológicos e seus fatores determinantes / Contamination rate of blood tests and its determining factors
Rubia-Ortí, José Enrique De La; Verdu-Trescolí, Gemma; Prado-Gascó, Vicente; Selvi-Sabater, Pablo; Firmino-Canhoto, Joao.
  • Rubia-Ortí, José Enrique De La; Universidade Europeia de Valência. Valencia. ES
  • Verdu-Trescolí, Gemma; Universidade Europeia de Valência. Valencia. ES
  • Prado-Gascó, Vicente; Universidade Europeia de Valência. Valencia. ES
  • Selvi-Sabater, Pablo; Universidade Europeia de Valência. Valencia. ES
  • Firmino-Canhoto, Joao; Universidade Europeia de Valência. Valencia. ES
Acta paul. enferm ; 27(2): 144-150, Mar-Apr/2014. tab, graf
Article Dans Portugais | LILACS-Express | LILACS, BDENF | ID: lil-712664
RESUMO

Objetivo:

Conhecer a taxa de contaminação de hemoculturas e os seus fatores determinantes.

Métodos:

Foram analisadas 564 amostras de hemoculturas requisitadas num serviço hospitalar de urgências e questionados 46 enfermeiras(os) durante um período de seis meses.

Resultados:

Produziram-se 92 contaminações de hemoculturas de um total de 564 requisições num período de seis meses, o que corresponde a uma taxa de contaminação de 16,31%. O fator determinante foi a utilização de técnica pouco estéril.

Conclusão:

A taxa de contaminação das hemoculturas está diretamente relacionada aos procedimentos utilizados pelos profissionais de enfermagem e a carga de trabalho está diretamente associada a erros na técnica estéril de coleta. .
ABSTRACT

Objective:

Determining the contamination rate of blood cultures and its determining factors.

Methods:

During a period of six months, were analyzed 564 blood culture samples requested at hospital emergency wards and 46 nurses were inquired.

Results:

In a period of six months, among a total of 564 requests, 92 blood cultures were contaminated, which corresponds to a contamination rate of 16.31%. The determining factor was the use of low-level sterile technique.

Conclusion:

The contamination rate of blood cultures is directly related to the procedures used by the nursing staff, and the workload is directly related to errors in the sterile technique of collection. .