Reprodutibilidade do teste de caminhada e do degrau de 6 minutos em adultos jovens saudáveis / Reproducibility of the six-minute walk and step tests in healthy young adults / Reproductibilidad del test de caminata y del escalón de 6 minutos en adultos jóvenes saludables
Davi, Simone Fernandes; Arcuri, Juliano Ferreira; Labadessa, Ivana Gonçalves; Pessoa, Bruna Varanda; Costa, Joyce Nogueira Ferreira da; Sentanin, Anna Cláudia; Lorenzo, Valéria Amorim Pires Di.
  • Davi, Simone Fernandes; Universidade Federal de São Carlos. São Carlos. BR
  • Arcuri, Juliano Ferreira; Universidade Federal de São Carlos. São Carlos. BR
  • Labadessa, Ivana Gonçalves; Universidade Federal de São Carlos. São Carlos. BR
  • Pessoa, Bruna Varanda; Universidade Federal de São Carlos. São Carlos. BR
  • Costa, Joyce Nogueira Ferreira da; Universidade Federal de São Carlos. São Carlos. BR
  • Sentanin, Anna Cláudia; Universidade Federal de São Carlos. São Carlos. BR
  • Lorenzo, Valéria Amorim Pires Di; Universidade Federal de São Carlos. São Carlos. BR
Rev. bras. med. esporte ; 20(3): 214-218, May-Jun/2014. tab, graf
Article Dans Portugais | LILACS | ID: lil-718418
RESUMO

INTRODUÇÃO:

Os testes caminhada de seis minutos (TC6) e degrau de seis minutos (TD6) são meios de avaliação da capacidade funcional. No entanto, pouco se sabe sobre sua reprodutibilidade em adultos jovens.

OBJETIVO:

Avaliar a reprodutibilidade relativa e absoluta tanto intra quanto inter-avaliadores do TC6 e TD6 em indivíduos adultos jovens.

MÉTODOS:

Foram avaliados 33 indivíduos adultos jovens aparentemente saudáveis por meio da espirometria; e realizados os testes TC6 e TD6. Três (T1, T2 e T3) TC6 e TD6 foram feitos em cada indivíduo, sendo o último de cada teste realizado por um avaliador diferente. Para a análise intra-avaliadores foram comparados os desempenhos do T1 e T2 enquanto que a análise inter-avaliadores foi feita pela comparação dos desempenhos do T3 com T1; T2; e escolha do melhor dos primeiros dois testes. Foi calculado o coeficiente de correlação intra-classe (CCI) como medida da reprodutibilidade relativa; o erro padrão de medida; a diferença mínima detectável; traçados gráficos de Bland-Altman e teste ANOVA para analisar a reprodutibilidade absoluta.

RESULTADOS:

Observaram-se, nos dois testes funcionais, intra e inter-avaliadores, valores excelentes de reprodutibilidade relativa (CCI>0,75) e a reprodutibilidade absoluta mostrou alto erro.

CONCLUSÃO:

O TD6 e o TC6 apresentaram reprodutibilidade intra e inter-avaliadores excelente para a população adulto jovem, mas altos valores de erro. .
ABSTRACT

INTRODUCTION:

Six Minute Walk Test (6MWT) and Six Minute Step Test (6MST) are tests to evaluate functional capacity. However, reproducibility of these tests is still not well known in young adults.

OBJECTIVE:

To evaluate intra and inter-rater relative and absolute reproducibility of 6MWT and 6MST in young adults.

METHODS:

Thirty-three apparently health young adults were evaluated through spirometry, 6MWT and 6MST. Three (T1, T2 and T3) of each 6MWT and 6MST were carried out on each individual, the latter (T3) by a different evaluator. Intra-rater analysis was performed comparing the performance of T1 and T2, while the inter-rater analysis was executed using the comparisons of T3 with T1, T2 and the best result of the first two. Intra-class correlation coefficient (ICC) was calculated as a measure of relative reproducibility; the standard error of measurement, minimal detectable change, Bland-Altman plots and repeated measures ANOVA were used to verify absolute reproducibility.

RESULTS:

Excellent values of relative reproducibility (ICC>0.75) were observed in both 6MWT and 6MST, yet high error values were found in absolute reproducibility analysis.

CONCLUSION:

6MWT and 6MST present excellent intra and inter-rater relative reproducibility, but high error values. .
RESUMEN

INTRODUCCIÓN:

Los tests de caminata de seis minutos (TC6) y escalón de seis minutos (TD6) son medios de evaluación de la capacidad funcional. Mientras tanto, poco se sabe sobre su reproductibilidad en adultos jóvenes.

OBJETIVO:

Evaluar la reproductibilidad relativa y absoluta tanto intra como inter-evaluadores del TC6 y TD6 en individuos adultos jóvenes.

MÉTODOS:

Fueron evaluados 33 individuos adultos jóvenes aparentemente saludables por medio de espirometría; y realizados los tests TC6 y TD6. Tres (T1, T2 y T3) TC6 y TD6 fueron hechos en cada individuo, siendo el último de cada test realizado por un evaluador diferente. Para el análisis intra-evaluadores fueron comparados los desempeños del T1 y T2 mientras que el análisis inter-evaluadores fue hecho por la comparación de los desempeños del T3 con T1; T2; y selección del mejor de los primeros dos tests. Fue calculado el coeficiente de correlación intra-clase (CCI) como medida de la reproductibilidad relativa; el Error Estándar de Medida; la diferencia mínima detectable; trazados gráficos de Bland-Altman y test ANOVA para analizar la reproductibilidad absoluta.

RESULTADOS:

Se observaron, en los dos tests funcionales, intra e inter-evaluadores, valores excelentes de reproductibilidad relativa (CCI>0,75) y la reproductibilidad absoluta mostró alto error.

CONCLUSIÓN:

El TD6 y el TC6 presentaron reproductibilidad intra e inter-evaluadores excelente para la población adulto joven, pero altos valores de error. .