Volume derramado, saturação de oxigênio e frequência cardíaca durante a alimentação de recém-nascidos prematuros: comparação entre dois métodos alternativos de oferta / Spilled volum, oxygen saturation, and heart rate during feeding of preterm newborns: comparison between two alternative feeding methods
CoDAS
; 28(3): 212-220, tab, graf
Article
de Pt
| LILACS
| ID: lil-788081
Bibliothèque responsable:
BR1.1
RESUMO
RESUMO Objetivo Comparar o uso da seringa e da técnica sonda-dedo para a oferta de dieta a prematuros, considerando-se volume de dieta oferecido e volume derramado, variação da saturação de oxigênio periférico e frequência cardíaca. Métodos Estudo quasi-experimental, com 30 prematuros, 13 do gênero feminino e 17 do masculino. As médias das idades gestacionais ao nascimento e no momento da avaliação (idade corrigida) foram de 33 4/7±4/7 e 36±4/7, respectivamente. Os pesos médios ao nascimento e na avaliação foram de 1.800±140 e 1.972±88 gramas. Foi avaliado um momento de alimentação com a seringa e outro com a sonda-dedo para a mesma criança, sendo caso e controle de si mesma. Utilizou-se oxímetro de pulso portátil para verificar a variação da saturação de oxigênio e a frequência cardíaca. Uma gaze foi colocada sob o queixo do bebê como anteparo da dieta derramada. Foram utilizados os testes ANOVA, t de Student pareado, Comparação Múltipla de Tukey e Correlação de Pearson, com nível de significância de 5%. Resultados Houve diferença para o volume oferecido e para o volume de leite derramado com os dois valores, sendo maiores quando a seringa foi utilizada. A frequência cardíaca foi diferente antes/durante e antes/depois para ambas as formas de oferta, mas com valores considerados normais, assim como a saturação de oxigênio, que apontou aumento entre os momentos antes e depois da oferta para a seringa. Conclusão A técnica sonda-dedo proporciona menor derramamento da dieta, sendo as variações da saturação de oxigênio e frequência cardíaca consideradas normais para o neonato.
ABSTRACT
ABSTRACT Purpose To compare the use of syringe and finger feeding to feed preterm newborns considering amount of milk offered, amount of milk spilled, variation of oxygen saturation, and heart rate. Methods Quasi-experimental study with 30 preterm newborns. Thirteen infants were females and 17 were males. The mean gestational age at birth and during evaluation (corrected age) was 33 4/7 ± 4/7 and 36 ± 4/7, respectively. Newborns’ mean birthweight and mean weight when evaluated was 1,800 ± 140 and 1,972 ± 88 grams. We assessed one feeding session using a syringe and another feeding session using the finger feeding technique. Both techniques were used in the same infant, so that the preterm newborns were controls for themselves. A portable pulse oximeter was used to check the variation of oxygen saturation and heart rate. A gauze pad was placed under the infants’ chin to absorb the spilled milk. The statistical tests used were ANOVA, paired Student’s t test, Tukey Multiple Comparison test, and Pearson Correlation Coefficient. The level of significance was set at 5%. Results We found a difference between the techniques in terms of both amount of milk offered and amount of milk spilled. These amounts were larger when the syringe was used. Heart rate was different at two specific times before/during and before/after feeding for both techniques. However, the values were within normal limits. Oxygen saturation values were also different, showing higher values after syringe feeding. Conclusions Finger feeding proved to cause less spillage, whereas the variations of oxygen saturation and heart rate were within normal limits.
Mots clés
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Consommation d'oxygène
/
Prématuré
/
Méthodes d'alimentation
/
Rythme cardiaque
Type d'étude:
Screening_studies
Limites du sujet:
Animals
/
Female
/
Humans
/
Male
langue:
Pt
Texte intégral:
CoDAS
Thème du journal:
AUDIOLOGIA
/
PATOLOGIA DA FALA E LINGUAGEM
Année:
2016
Type:
Article