The depletion of water resources, both surface and subsurface and deterioration of water quality made researchers and policy makers to think of the possible remedies to make water sources potable / wholesome. There is a need to address the problems of hardness and fluoride in subsurface water on priority basis. In this direction, bench scale studies were conducted to evaluate the performance of water softeners. Indepth studies were carried out at University B.D.T College of Engineering, Davangere, Karnataka, to assess the performance of bench scale softeners of D to H ratio 12, 13, 14 in removing hardness of varied concentrations from both synthetic and natural water samples. Studies revealed that irrespective of D to H ratio of softeners, the waters having hardness concentration up to 1000 mg/l can be treated to the same degree (81.68% and above). The findings of regeneration studies and cost economics are also summarized in this paper.