Perioperative issues due to long-standing lung collapse during repair of a large ascending aortic aneurysm.
Ann Card Anaesth ; 2008 Jul-Dec; 11(2): 119-22
Article Dans Anglais | IMSEAR | ID: sea-1438
ABSTRACT
Acute lung collapse during open-heart surgery may potentially lead to problems such as inadequate gas exchange, increased pulmonary vascular resistance, increased afterload to the right ventricle, and difficulty in weaning from cardiopulmonary bypass (CPB). Therefore, expansion of the lungs is ensured prior to separation from CPB. We report the inability to manually expand a chronically collapsed lung during the repair of ascending aortic aneurysm. The collapsed lung did not pose difficulty in separation from CPB and in blood gas management during the perioperative period. We discuss perioperative management issues in such situations.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Anévrysme de l'aorte / Complications postopératoires / Atélectasie pulmonaire / Femelle / Humains / Pontage cardiopulmonaire / Maladie chronique / Soins périopératoires / Implantation de prothèses vasculaires / Adulte d'âge moyen langue: Anglais Texte intégral: Ann Card Anaesth Année: 2008 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Anévrysme de l'aorte / Complications postopératoires / Atélectasie pulmonaire / Femelle / Humains / Pontage cardiopulmonaire / Maladie chronique / Soins périopératoires / Implantation de prothèses vasculaires / Adulte d'âge moyen langue: Anglais Texte intégral: Ann Card Anaesth Année: 2008 Type: Article