Modified snap-on attachment with 'O-ring' for two piece hollow bulb obturator.
Article de En | IMSEAR | ID: sea-148741
Restoration of near normal functions in patients who have been treated with hemimaxillectomy is generally difficult, in view of the restriction in mouth opening following healing of large surgical wound. Further, the extent and nature of the surgical defect differ from patient to patient. Thus, design of an obturator needs to be patient oriented. In this report, we describe a novel snap-on attachment with O-ring in a conventional two piece hollow bulb obturator for a 70-year-old male treated for carcinoma of the left maxilla and sinus.
Mots clés
Texte intégral: 1 Indice: IMSEAR langue: En Année: 2013 Type: Article