Your browser doesn't support javascript.
loading
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty.
Article Dans Anglais | IMSEAR | ID: sea-38228
ABSTRACT

OBJECTIVE:

To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. MATERIAL AND

METHOD:

Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medium-term results were analyzed. The immediate results were classified into two groups based on the pulmonary systolic pressure gradient (PG) immediately after dilation group 1 with a PG < or = 35 mmHg and group II with a PG > 35 mmHg. At medium-term follow-up of 6 to 60 months, echocardiographic evaluations were analyzed and divided into two groups group A with a PG < or = 25 mmHg and group B with a PG > 25 mmHg. Demographic characteristics and hemodynamic parameters of immediate and medium-term results were compared and analyzed.

RESULTS:

Immediately after PBV the right ventricular systolic pressure (RVSP) decreased from 115.3 +/- 37.6 mmHg to 67.0 +/- 28.5 mmHg (p < 0.001). The pulmonary systolic pressure gradient decreased from 90.4 +/- 37.9 mmHg to 39.3 +/- 25.6 mmHg (p < 0.001). Nine of the 25 patients (group 11; 36%), with incomplete immediate relief of the obstruction, had more symptoms, a higher baseline PG, higher right atrial pressure, higher RVSP, and a higher systolic pressure ratio. Six of the 25 patients (group B; 24%), with suboptimal medium-term results, had a higher right ventricular voltage on the electrocardiogram, higher pre-dilation PG, and higher RVSP.

CONCLUSION:

Successful medium-term outcomes following pulmonary balloon valvuloplasty were achieved in 76% of the patients, with a greater success rate (91%) in patients with a lower right ventricular voltage electrocardiogram (R wave amplitude in V1) < or = 21 mm, a prevalvuloplasty systolic gradient < or = 90 mmHg, and right ventricular systolic pressure < or = 125 mmHg.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Sténose de la valve pulmonaire / Facteurs temps / Pression sanguine / Femelle / Humains / Mâle / Enfant / Enfant d&apos;âge préscolaire / Adolescent / Électrocardiographie langue: Anglais Année: 2006 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Sténose de la valve pulmonaire / Facteurs temps / Pression sanguine / Femelle / Humains / Mâle / Enfant / Enfant d&apos;âge préscolaire / Adolescent / Électrocardiographie langue: Anglais Année: 2006 Type: Article