Experiment of intranasal synthetic filter for prevention of suspended particulated matter: rhinomanometric evaluation.
Article Dans Anglais | IMSEAR | ID: sea-40516
ABSTRACT
The experimental study of intranasal synthetic filter with stent was tried to decrease suspended particulate matter for human respiratory tract. Facial mask or surgical mask were evaluated. Nasal vestibular size in Thai adults was estimated. Different kinds of stents and filters were used. Standard anterior rhinomanometry was the proper objective method to test nasal air flow resistant of stent and filter. Nasal obstructive symptom correlated well with rhinomanometric results. One layer of outer and inner face mask at each end of the cylindrical silicone stent was the suitable device. There were no complications or side effects. This personal protective device was cheap and available. The filtration efficacy should be tested in a general population during a highly air-polluted period.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Dispositifs de protection / Thaïlande / Emissions des véhicules / Sujet âgé / Femelle / Humains / Mâle / Administration par voie nasale / Obstruction nasale / Endoprothèses Pays comme sujet: Asie langue: Anglais Année: 1998 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Dispositifs de protection / Thaïlande / Emissions des véhicules / Sujet âgé / Femelle / Humains / Mâle / Administration par voie nasale / Obstruction nasale / Endoprothèses Pays comme sujet: Asie langue: Anglais Année: 1998 Type: Article