Correction of truncus arteriosus using a fresh autologous pericardial trileaflet valve conduit.
Article Dans Anglais | IMSEAR | ID: sea-40939
ABSTRACT
A fresh autologous pericardial trileaflet valve conduit was used in a 5-month-old infant for correction of truncus arteriosus. The patient recovered from the operation with satisfactory hemodynamics and post-operative echocardiogram at 3 months showed only mild to moderate pulmonary regurgitation. This technique is a useful alternative for correction in an infant with congenital heart disease who needs a tissue valve conduit. It may be more suitable than an aortic homograft by reason of unavailability of small homograft and limitation of organ donation.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Péricarde / Transplantation autologue / Tronc artériel commun / Humains / Mâle / Implantation de prothèses vasculaires / Procédures de chirurgie cardiaque / Valves cardiaques / Nourrisson langue: Anglais Année: 2002 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Péricarde / Transplantation autologue / Tronc artériel commun / Humains / Mâle / Implantation de prothèses vasculaires / Procédures de chirurgie cardiaque / Valves cardiaques / Nourrisson langue: Anglais Année: 2002 Type: Article