Transconjunctival orbital emphysema caused by compressed air injury: a case report.
Indian J Ophthalmol ; 2008 May-Jun; 56(3): 247-9
Article Dans Anglais | IMSEAR | ID: sea-71000
ABSTRACT
Orbital emphysema following conjunctival tear in the absence of orbital wall fracture, caused by air under pressure is rare. Usually orbital emphysema is seen in facial trauma associated with damage to the adjacent paranasal sinuses or facial bones. To the best of our knowledge, there have been only eight reports of orbital emphysema following use of compressed air during industrial work. The air under pressure is pushed through the subconjunctival space into the subcutaneous and retrobulbar spaces. We present here a rare cause of orbital emphysema in a young man working with compressed air gun. Although the emphysema was severe, there were no orbital bone fracture and the visual recovery of the patient was complete without attendant complications.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Maladies de l'orbite / Humains / Mâle / Accidents du travail / Tomodensitométrie / Lésions traumatiques de l'oeil / Conjonctive / Adulte / Air / Emphysème langue: Anglais Texte intégral: Indian J Ophthalmol Année: 2008 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Maladies de l'orbite / Humains / Mâle / Accidents du travail / Tomodensitométrie / Lésions traumatiques de l'oeil / Conjonctive / Adulte / Air / Emphysème langue: Anglais Texte intégral: Indian J Ophthalmol Année: 2008 Type: Article