Achievement of surgically soft and safe eyes--a comparative study.
Indian J Ophthalmol ; 1991 Jan-Mar; 39(1): 12-4
Article Dans Anglais | IMSEAR | ID: sea-71220
ABSTRACT
With the advent of intra ocular lens implantation at the time of cataract extraction, especially by intracapsular method, it has become very important to prevent the loss of vitreous during surgery. This can be achieved by lowering the intraocular pressure by various methods. In order to find out the best method to achieve a soft & safe eye before surgery, a study was conducted on 90 patients, undergoing intracapsular cataract extraction. The patients were divided into 9 groups of 10 each, & different methods of lowering intraocular pressure were tried and results compared. It was observed that intravenous mannitol given preoperatively and pressure with mercury column together, formed the best combination to achieve the maximum tension lowering effect.
Sujets)
Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Prémédication / Sujet âgé / Femelle / Humains / Mâle / Extraction de cataracte / Pression intraoculaire / Lentilles intraoculaires / Mannitol / Adulte d'âge moyen langue: Anglais Texte intégral: Indian J Ophthalmol Année: 1991 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: IMSEAR (Asie du Sud-Est) Sujet Principal: Prémédication / Sujet âgé / Femelle / Humains / Mâle / Extraction de cataracte / Pression intraoculaire / Lentilles intraoculaires / Mannitol / Adulte d'âge moyen langue: Anglais Texte intégral: Indian J Ophthalmol Année: 1991 Type: Article