Your browser doesn't support javascript.
loading
HIV Ag-Abdetection by ELISA: a retrospective analysis / 中国输血杂志
Chinese Journal of Blood Transfusion ; (12): 216-218, 2022.
Article Dans Chinois | WPRIM | ID: wpr-1004348
ABSTRACT
【Objective】 To conduct a retrospective analysis of HIV Ag-Ab detection by ELISA in our blood center, so as to provide reference for continuous improvement. 【Methods】 The reactive rate of HIV by each reagent, reactive rate of both reagents, re-test rate, concordance rate of initial-repeat test, and reagent utilization rate were counted, and the external quality assessment results were analyzed by PT score and z-ratio. 【Results】 The total reactive rate of HIV was 0.15%. The reactive rate by both reagents was 0.02%. The re-test rates, reactive rates, concordance rates and reagent utilization rates of the two reagents were 0.09% vs 0.08%, 0.07% vs 0.06%, 75.86% vs 78.21%, and 114.54% vs 113.92%, respectively. PT score was 100%, and z-ratio of 7 negative samples and 1 positive sample was less than 2, and of 2 positive samples was more than 3. 【Conclusion】 The laboratory quality monitoring indicators and external quality assessment can effectively monitor the operation of blood testing laboratory.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Blood Transfusion Année: 2022 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Blood Transfusion Année: 2022 Type: Article