A preliminary analysis of individual neutron dose monitoring with 6LiF-7LiF and CR39 / 中国辐射卫生
Chinese Journal of Radiological Health
;
(6): 626-631, 2023.
Article
Dans Chinois
| WPRIM
| ID: wpr-1006317
ABSTRACT
Objective To preliminarily compare 6LiF-7LiF and CR39 in individual neutron dose monitoring, and to provide a reference for improving individual neutron dose monitoring. Methods According to the GBZ 128-2019, 26 radiation workers from 7 institutions received individual neutron dose monitoring with 6LiF-7LiF and CR39 at the same time. The monitoring results were analyzed. Results For most of the workers, the personal neutron dose equivalent Hp(10) was less than the minimum detectable level. The results with the two monitoring methods differed in 6 of 26 workers. Conclusion Both 6LiF-7LiF and CR39 monitoring methods can be used for individual neutron dose monitoring for radiation workers, but the difference between 6LiF-7LiF and CR39 (in threshold energy, energy response, etc.) should be considered so that different types of radiation workers receive appropriate individual neutron dose monitoring.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
langue:
Chinois
Texte intégral:
Chinese Journal of Radiological Health
Année:
2023
Type:
Article