Easy Identification of Mechanical Axis during Total Knee Arthroplasty
Yonsei med. j
; Yonsei med. j;: 1505-1510, 2013.
Article
de En
| WPRIM
| ID: wpr-100946
Bibliothèque responsable:
WPRO
ABSTRACT
PURPOSE: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). MATERIALS AND METHODS: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. RESULTS: The alignment of the lower extremity improved from a mean of 11.4+/-6.7degrees (-10.3-34.4degrees) of varus preop. to 0.7+/-3.5degrees (-5.2-8.6degrees) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3+/-2.3degrees (83.4-97.2degrees) postop. and mean alignment of the tibial component was 90.4+/-2.2degrees (85.1-94.2degrees) postop. CONCLUSION: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.
Mots clés
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Tibia
/
Arthroplastie prothétique de genou
/
Fémur
Type d'étude:
Diagnostic_studies
Limites du sujet:
Humans
langue:
En
Texte intégral:
Yonsei med. j
Année:
2013
Type:
Article