Diagnostic efficacy of prostate cancer using targeted biopsy with 6-core systematic biopsy for patients with PI-RADS 5 / 北京大学学报(医学版)
Journal of Peking University(Health Sciences)
;
(6): 812-817, 2023.
Article
Dans Chinois
| WPRIM
| ID: wpr-1010134
ABSTRACT
OBJECTIVE@#To investigate the diagnostic efficacy of targeted biopsy (TBx), systematic biopsy (SBx), TBx+6-core SBx in prostate cancer (PCa) / clinically significant prostate cancer (cs-PCa) for patients with prostate imaging reporting and data system (PI-RADS) score of 5, and thereby to explore an optimal sampling scheme.@*METHODS@#The data of 585 patients who underwent multiparametric magnetic resonance imaging (mpMRI) with at least one lesion of PI-RADS score 5 at Peking University First Hospital from January 2019 to June 2022 were retrospectively analyzed. All patients underwent mpMRI / transrectal ultrasound (TRUS) cognitive guided biopsy (TBx+SBx). With the pathological results of combined biopsy as the gold standard, we compared the diagnostic efficacy of TBx only, SBx only, and TBx+6-core SBx for PCa/csPCa. The patients were grouped according to mpMRI T-stage (cT2, cT3, cT4) and the detection rates of different biopsy schemes for PCa/csPCa were compared using Cochran's Q and McNemar tests.@*RESULTS@#Among 585 patients with a PI-RADS score of 5, 560 (95.7%) were positive and 25(4.3%) were negative via TBx+SBx. After stratified according to mpMRI T-stage, 233 patients (39.8%) were found in cT2 stage, 214 patients (36.6%) in cT3 stage, and 138 patients (23.6%) in cT4 stage. There was no statistically significant difference in the detection rate of PCa/csPCa between TBx+6-core SBx and TBx+SBx (all P>0.999). Also, there was no statistically significant difference in the detection rate of PCa/csPCa between TBx and TBx+SBx in the cT2, cT3, and cT4 subgroups (PCa P=0.203, P=0.250, P>0.999; csPCa P=0.700, P=0.250, P>0.999). The missed diagnosis rate of SBx for PCa and csPCa was 2.1% (12/560) and 1.8% (10/549), and that of TBx for PCa and csPCa was 1.8% (10/560) and 1.4% (8/549), respectively. However, the detection rate of TBx+6-core SBx for PCa and csPCa was 100%. Compared with TBx+SBx, TBx and TBx+6-core SBx had a fewer number of cores and a higher detection rate per core (P < 0.001).@*CONCLUSION@#For patients with a PI-RADS score of 5, TBx and TBx+6-core SBx showed the same PCa/csPCa detection rates and a high detection rates per core as that of TBx+SBx, which can be considered as an optimal scheme for prostate biopsy.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Prostate
/
Tumeurs de la prostate
/
Imagerie par résonance magnétique
/
Études rétrospectives
/
Biopsie guidée par l'image
Limites du sujet:
Humains
/
Mâle
langue:
Chinois
Texte intégral:
Journal of Peking University(Health Sciences)
Année:
2023
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS