A Case of Functional Bitemporal Hemianopia Respecting the Vertical Meridian
Journal of the Korean Ophthalmological Society ; : 957-962, 2009.
Article Dans Coréen | WPRIM | ID: wpr-10532
ABSTRACT

PURPOSE:

To report a case of functional bilateral hemianopia which was not associated with any organic causes. CASE

SUMMARY:

A 35-year-old female patient presented with bilateral disturbance of visual acuity and visual field, which had begun 8 months prior. Goldmann perimetry showed bitemporal hemianopsia respecting the vertical meridian. Pupillary response was normal, and the anterior segment, fundus, and optic nerve were also normal bilaterally. However, the tangent screen test and Humphrey visual field test showed a widening of hemianopia not respecting the vertical meridian, and the crossing of isopters at 1 m and 2 m with the tangent screen test. In addition, multifocal electroretinogram and multifocal visual evoked potential did not reveal any abnormal findings corresponding to the bitemporal hemianopia. Brain magnetic resonance imaging showed no abnormal findings in the orbit and brain.

CONCLUSIONS:

Bitemporal hemianopsia can be developed functionally, although it may be rare. Repetition of various visual field tests and use of multifocal electrophysiologic studies can be helpful in the differential diagnosis.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Nerf optique / Orbite / Encéphale / Imagerie par résonance magnétique / Acuité visuelle / Champs visuels / Hémianopsie / Diagnostic différentiel / Potentiels évoqués visuels / Tests du champ visuel Type d'étude: Etude diagnostique Limites du sujet: Adulte / Femelle / Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2009 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Nerf optique / Orbite / Encéphale / Imagerie par résonance magnétique / Acuité visuelle / Champs visuels / Hémianopsie / Diagnostic différentiel / Potentiels évoqués visuels / Tests du champ visuel Type d'étude: Etude diagnostique Limites du sujet: Adulte / Femelle / Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2009 Type: Article