Your browser doesn't support javascript.
loading
Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 431-434, 2007.
Article Dans Coréen | WPRIM | ID: wpr-113021
ABSTRACT

PURPOSE:

The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness.

METHODS:

From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation.

RESULTS:

The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact.

CONCLUSION:

The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Perfusion / Peau / Matériaux de suture / Plaies et blessures / Oestrogènes conjugués (USP) / Lambeaux tissulaires libres / Laparotomie / Mésentère / Muqueuse / Cou Type d'étude: Étude de dépistage langue: Coréen Texte intégral: Journal of the Korean Society of Plastic and Reconstructive Surgeons Année: 2007 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Perfusion / Peau / Matériaux de suture / Plaies et blessures / Oestrogènes conjugués (USP) / Lambeaux tissulaires libres / Laparotomie / Mésentère / Muqueuse / Cou Type d'étude: Étude de dépistage langue: Coréen Texte intégral: Journal of the Korean Society of Plastic and Reconstructive Surgeons Année: 2007 Type: Article