Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test
The Korean Journal of Pain ; : 286-290, 2013.
Article de En | WPRIM | ID: wpr-12383
Bibliothèque responsable: WPRO
ABSTRACT
Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours.
Sujet(s)
Mots clés
Texte intégral: 1 Indice: WPRIM Sujet Principal: Paraplégie / Injections épidurales / Imagerie par résonance magnétique / Membre inférieur / Espace épidural / Hypoesthésie Limites du sujet: Female / Humans langue: En Texte intégral: The Korean Journal of Pain Année: 2013 Type: Article
Texte intégral: 1 Indice: WPRIM Sujet Principal: Paraplégie / Injections épidurales / Imagerie par résonance magnétique / Membre inférieur / Espace épidural / Hypoesthésie Limites du sujet: Female / Humans langue: En Texte intégral: The Korean Journal of Pain Année: 2013 Type: Article