PURPOSE:
To determine the frequency of complications and diagnostic accuracy of CT-guided percutaneous automated gun biopsy, and to compare the results with those reported for fine needle aspiration. MATERIALS ANDMETHODS:
Using automated biopsy devices, 118 CT-guided percutaneous biopsies of pulmonary lesions were performed. An 18-gauge needle was used. Final diagnosis was made with operation or other methods. We retrospectively analyzed the frequency of complications and diagnostic yields of 118 biopsies.RESULT:
Four of 118(3.3%) patients developed pneumothorax and two of these required chest tube insertion. Other complications were resolved spontaneously. 106 biopsies (89.8%) yielded sufficient tissue for pathologic evaluation. For cases of malignant and of benign disease, sensitivity was 91.8% and 87.7% respectively ; the corresponding figures for diagnostic accuracy were 88.5% and 78.9%.CONCLUSION:
CT-guided automated gun biopsy of the pulmonary lesions is safe, witha pneumothorax rate comparable to that of fine needle aspiration. In the absence of a trained cytologist at the time of biopsy, the diagnostic accuracy of automated gun biopsy of pulmonary lesions compared favorably with the reported accuracy of fine needle aspiration.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Pneumothorax
/
Biopsie
/
Drains thoraciques
/
Études rétrospectives
/
Cytoponction
/
Diagnostic
/
Aiguilles
Type d'étude:
Etude diagnostique
/
Étude observationnelle
langue:
Coréen
Texte intégral:
Journal of the Korean Radiological Society
Année:
1996
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS