The Proper Volume and Distribution of Cement Augmentation on Percutaneous Vertebroplasty
Journal of Korean Neurosurgical Society ; : 125-128, 2010.
Article Dans Anglais | WPRIM | ID: wpr-147244
ABSTRACT

OBJECTIVE:

The purpose of this study was to determine the optimal volume of injected cement and its distribution when used to treat vertebral compression fractures, and to identify factors related to subsequent vertebral fractures.

METHODS:

A retrospective analysis of newly developing vertebral fractures after percutaneous vertebroplasty was done. The inclusion criteria were that the fracture was a single first onset fracture with exclusion of pathologic fractures. Forty-three patients were included in the study with a minimum follow up period of six months. Patients were dichotomized for the analysis by volume of cement, initial vertebral height loss, bone marrow density, and endplate-to-endplate cement augmentation.

RESULTS:

None of the four study variables was found to be significantly associated with the occurrence of a subsequent vertebral compression fracture. In particular, and injected cement volume of more or less that 3.5 cc was not associated with occurrence (p = 0.2523). No relation was observed between initial vertebral height loss and bone marrow density (p = 0.1652, 0.2064). Furthermore, endplate-to-endplate cement augmentation was also not found to be significantly associated with a subsequent fracture (p = 0.2860) by Fisher's exact test.

CONCLUSION:

Neither volume of cement, initial vertebral height loss, bone marrow density, or endplate-to-endplate cement augmentation was found to be significantly related to the occurrence of a subsequent vertebral compression fracture. Our findings suggest that as much cement as possible without causing leakage should be used.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Moelle osseuse / Études rétrospectives / Études de suivi / Fractures par compression / Vertébroplastie / Fractures spontanées Type d'étude: Étude observationnelle / Étude pronostique / Facteurs de risque Limites du sujet: Humains langue: Anglais Texte intégral: Journal of Korean Neurosurgical Society Année: 2010 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Moelle osseuse / Études rétrospectives / Études de suivi / Fractures par compression / Vertébroplastie / Fractures spontanées Type d'étude: Étude observationnelle / Étude pronostique / Facteurs de risque Limites du sujet: Humains langue: Anglais Texte intégral: Journal of Korean Neurosurgical Society Année: 2010 Type: Article