Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI
Yonsei Medical Journal
;
: 1186-1194, 2017.
Article
Dans Anglais
| WPRIM
| ID: wpr-15474
ABSTRACT
PURPOSE:
To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). MATERIALS ANDMETHODS:
One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively reviewed. Using arthroscopic results and two-dimensional images as reference standards, diagnostic performances of 3D FSE-Cube-NFS and FS imaging about lesions of ligament, meniscus, subchondral bone marrow edema (BME), and cartilage were compared. Scan parameters of 3D FSE-Cube imaging were previously optimized by a porcine knee phantom.RESULTS:
No significant differences were observed between detection rates of NFS and FS imaging for detecting lesions of meniscus and cartilage (p>0.05). However, NFS imaging had lower sensitivity for detection of medial collateral ligament (MCL) tears, and lower sensitivity and specificity for detection of BME lesions, compared to FS imaging (p<0.05).CONCLUSION:
3D FSE-Cube-NFS imaging showed similar diagnostic performance for detecting lesions of meniscus or cartilage compared to FS imaging, unlike MCL or BME lesions.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Arthroscopie
/
Larmes
/
Moelle osseuse
/
Imagerie par résonance magnétique
/
Cartilage
/
Études rétrospectives
/
Sensibilité et spécificité
/
Ligaments collatéraux
/
Imagerie tridimensionnelle
/
Oedème
Type d'étude:
Etude diagnostique
/
Guide de pratique
/
Étude observationnelle
Limites du sujet:
Humains
langue:
Anglais
Texte intégral:
Yonsei Medical Journal
Année:
2017
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS