A Case of Iatrogenic Horner's Syndrome after Video-Thoracoscopic Surgery for Primary Pneumothorax
Journal of the Korean Ophthalmological Society ; : 157-160, 2012.
Article Dans Coréen | WPRIM | ID: wpr-161765
ABSTRACT

PURPOSE:

To report a case of iatrogenic Horner's syndrome after video-thoracoscopic surgery for primary pneumothorax. CASE

SUMMARY:

An 18-year-old man with ptosis in the right eye was referred to our clinic. The patient had undergone wedge resection via video-thoracoscopic surgery for primary pneumothorax three weeks previously. On ocular examination, the palpebral fissure width was 7 mm in the right lid and 8 mm in the left lid, the marginal reflex distance 1 (MRD 1) was 2 mm in the right lid and 3 mm in the left lid, and the bilateral levator muscle function was good. Anisocoria was present, and pupil size in a dark room was 2.5 mm in the right eye and 4 mm in the left eye. The patient complained of facial anhidrosis on the right side of the face.

CONCLUSIONS:

Although iatrogenic Horner's syndrome is rare complication of video-thoracoscopic surgery for primary pneumothorax, diagnosis after surgery of the thoracic cavity should be made carefully.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Pneumothorax / Réflexe / Anisocorie / Pupille / Syndrome de Claude Bernard-Horner / Cavité thoracique / Oeil / Hypohidrose / Muscles Limites du sujet: Adolescent / Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2012 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Pneumothorax / Réflexe / Anisocorie / Pupille / Syndrome de Claude Bernard-Horner / Cavité thoracique / Oeil / Hypohidrose / Muscles Limites du sujet: Adolescent / Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2012 Type: Article