Your browser doesn't support javascript.
loading
Radiofrequency Ablation with Epinephrine Injection: In Vivo Study in Normal Pig Livers
Journal of the Korean Radiological Society ; : 51-59, 2007.
Article Dans Anglais | WPRIM | ID: wpr-161824
ABSTRACT

PURPOSE:

We wanted to evaluate whether epinephrine injection prior to radiofrequency (RF) ablation can increase the extent of thermally mediated coagulation in vivo normal pig liver tissue. MATERIALS AND

METHODS:

Eighteen RF ablation zones were created in six pigs using a 17-gauge internally cooled electrode under ultrasound guidance. Three RF ablation zones were created in each pig under three conditions RF ablation alone, RF ablation after the injection of 3 mL of normal saline, and RF ablation after the injection of 3 mL of epinephrine (110,000 solution). After the RF ablation, we measured the short and long diameters of the white zones in the gross specimens.

RESULTS:

Three of the RF ablations were technically unsuccessful; therefore, measurement of white zone was finally done in 15 RF ablation zones. The mean short and long diameters of the white zone of the RF ablation after epinephrine injection (17.2 mm +/- 1.8 and 20.8 mm +/- 3.7, respectively) were larger than those of RF ablation only (10 mm +/- 1.2 and 12.2 mm +/- 1.1, respectively) and RF ablation after normal saline injection (12.8 mm +/- 1.5 and 15.6 mm +/- 2.5, respectively) (p < .05).

CONCLUSION:

RF ablation with epinephrine injection can increase the diameter of the RF ablation zone in normal pig liver tissue.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Suidae / Épinéphrine / Échographie / Ablation par cathéter / Électrodes / Foie Type d'étude: Etude diagnostique Limites du sujet: Animaux langue: Anglais Texte intégral: Journal of the Korean Radiological Society Année: 2007 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Suidae / Épinéphrine / Échographie / Ablation par cathéter / Électrodes / Foie Type d'étude: Etude diagnostique Limites du sujet: Animaux langue: Anglais Texte intégral: Journal of the Korean Radiological Society Année: 2007 Type: Article