Improvement of Infraorbital Rim contour Using Medpor
Archives of Craniofacial Surgery
;
: 77-81, 2016.
Article
Dans Anglais
| WPRIM
| ID: wpr-163193
ABSTRACT
BACKGROUND:
Asymmetry of the infraorbital rim can be caused by trauma, congenital or acquired disease, or insufficient reduction during a previous operation. Such asymmetry needs to be corrected because the shape of the infraorbital rim or midfacial skeleton defines the overall midfacial contour.METHODS:
The study included 5 cases of retruded infraorbital rim. All of the patient underwent restoration of the deficient volume using polyethylene implants between June 2005 and June 2011. The infraorbital rim was accessed through a subciliary approach, and the implants were placed in subperiosteal space. Surgical outcomes were evaluated using preoperative and postoperative computed tomography studies.RESULTS:
Implant based augmentation was associated with a mean projection of 4.6 mm enhancement. No postoperative complications were noted during the 30-month follow-up period.CONCLUSION:
Because of the safeness, short recovery time, effectiveness, reliability, and potential application to a wide range of facial disproportion problems, this surgical technique can be applied to midfacial retrusion from a variety of etiologies, such as fracture involving infraorbital rim, congenital midfacial hypoplasia, lid malposition after blepharoplasty, and skeletal changes due to aging.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Complications postopératoires
/
Squelette
/
Vieillissement
/
Études de suivi
/
Blépharoplastie
/
Polyéthylène
Type d'étude:
Étude observationnelle
/
Étude pronostique
/
Facteurs de risque
Limites du sujet:
Humains
langue:
Anglais
Texte intégral:
Archives of Craniofacial Surgery
Année:
2016
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS