Breakage of a thoracic epidural catheter during its removal: A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 569-572, 2010.
Article Dans Anglais | WPRIM | ID: wpr-170119
ABSTRACT
The breakage of an epidural catheter is a rare complication during the removal of a thoracic epidural catheter. There are many causes to breakage of an epidural catheter, such as the characteristics of the catheter itself, patient's factors (anatomy, position during insertion and removal of the catheter, and the BMI), and the difficulty of the procedure. Surgical removal is considered if there is a possibility that the retained catheter might cause neurological problems. We experienced a breakage of an epidural catheter during its removal, which led to surgical intervention. To prevent the catheter breakage during its removal, the catheter should be withdrawn without excessive tension. In addition, an understanding of the patient's anatomy is essential.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Cathéters langue: Anglais Texte intégral: Korean Journal of Anesthesiology Année: 2010 Type: Article