BACKGROUND/AIM:
There is little data on whether plastic stents with a larger diameter are patent for longer than small stents in patients with bile duct cancer. The aim of this study was to compare the stent survival between 7-French (Fr) and 10-Fr plastic stents and evaluate the factors affecting stent survival.METHODS:
Patients with biliary obstruction due to biliary tract cancer were enrolled at Yonsei University Wonju College of Medicine from January 2010 to October 2014.RESULTS:
A total of 215 patients (7-Fr10-Fr = 89126 patients) were retrospectively enrolled. The primary tumor sites were common bile duct (n = 111), hilar (n = 45), and ampulla of Vater (n = 59). Rates of stent migration and stent obstruction were not different between the two groups. The median duration of stent survival was 3.3 months in the 7-Fr group and 5.9 months in the 10-Fr group (p = 0.543). The diameter of the stent did not have an effect on stent survival (hazard ratio 1.11, 95% confidence interval 0.71-1.73, p = 0.649).CONCLUSIONS:
7-Fr and 10-Fr stents have similar rates of stent migration and stent obstruction. The stent survival of 7-Fr was not inferior to 10-Fr stents in the management of biliary tract cancer.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Matières plastiques
/
Ampoule hépatopancréatique
/
Tumeurs des canaux biliaires
/
Voies biliaires
/
Tumeurs des voies biliaires
/
Endoprothèses
/
Études rétrospectives
/
Conduit cholédoque
Type d'étude:
Étude observationnelle
Limites du sujet:
Humains
langue:
Anglais
Texte intégral:
Korean Journal of Pancreas and Biliary Tract
Année:
2017
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS