Your browser doesn't support javascript.
loading
Evaluation of Abbott Fourth Generation HIV Antigen and Antibody Assays / 대한진단검사의학회지
The Korean Journal of Laboratory Medicine ; : 39-44, 2006.
Article Dans Coréen | WPRIM | ID: wpr-190581
ABSTRACT

BACKGROUND:

In order to reduce the diagnostic window period between the time of human immunodeficiency virus (HIV) infection and serological diagnosis, new fourth generation screening assays which detect HIV p24 antigen and specific antibody simultaneously have been developed. In this study, we evaluated the performance of a new fourth generation assay.

METHODS:

We compared a new fourth generation assay, Architect HIV Ag/Ab combo, with another fourth generation assay AxSYM HIV Ag/Ab combo and a third generation assay, AxSYM HIV 1/2 gO for their performance. The assays were evaluated using 3 HIV seroconversion panels, 305 sera of healthy subjects and 100 sera of patients with HBsAg or anti-HCV antibodies. Within-run and total coefficient variations of the three screening assays were analyzed for the evaluation of precision.

RESULTS:

Architect HIV Ag/Ab combo shortened the window period by 8.7+/-2.1 days relative to AxSYM HIV 1/2 gO and 2.0+/-2.0 days relative to AxSYM HIV Ag/Ab combo in seroconversion panels. Architect HIV Ag/Ab combo presented the best performance in precision among the three reagents; total CV for positive control was 3.6%, 9.6% and 4.6% for Architect HIV Ag/Ab combo, AxSYM HIV Ag/Ab combo and AxSYM HIV 1/2 gO, respectively. Specificities of three assays were not different in this study.

CONCLUSIONS:

HIV Ag/Ab combined assays reduced the diagnostic window as compared to the third generation screening assays, enabling an earlier diagnosis of HIV infection. A new fourth generation assay, Architect HIV Ag/Ab combo presents a better performance than AxSYM HIV Ag/Ab combo, showing improved seroconversion sensitivity and precision.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Infections à VIH / Dépistage de masse / VIH (Virus de l'Immunodéficience Humaine) / Séropositivité VIH / Protéine de capside p24 du VIH / Anticorps de l'hépatite C / Diagnostic / Antigènes de surface du virus de l'hépatite B / Indicateurs et réactifs Type d'étude: Etude diagnostique / Étude de dépistage Limites du sujet: Humains langue: Coréen Texte intégral: The Korean Journal of Laboratory Medicine Année: 2006 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Infections à VIH / Dépistage de masse / VIH (Virus de l'Immunodéficience Humaine) / Séropositivité VIH / Protéine de capside p24 du VIH / Anticorps de l'hépatite C / Diagnostic / Antigènes de surface du virus de l'hépatite B / Indicateurs et réactifs Type d'étude: Etude diagnostique / Étude de dépistage Limites du sujet: Humains langue: Coréen Texte intégral: The Korean Journal of Laboratory Medicine Année: 2006 Type: Article